4.1 FAULTS, CAUSES AND REMEDIES

Our after-sales staff can be contacted by telephone (+39 0546 26834), fax (+39 0546 665653) or e-mail
(assistenza@legaitaly.com), for any information or technical advice in regard to the machine; however, before
contacting our after-sales service, please check the information provided here below.
Screw feeder will not rotate
1)
The machine is not powered.
- Check for power line continuity.
2)
A foreign object in the screw feeder prevents rotation.
- Check and reverse the screw direction of rotation if necessary.
3)
Verify that the rotation time has not been set to zero (see 3.1.1 above)
Constantly noisy operation
1)
The bearings might be damaged.
- Remove the screw feeder pin from the gearmotor and check bearings condition.