If you chose DOOR as machine type, you will see
the following menu...
E
N
RINSE LIMIT:
G
30 SEC
L
I
This feature will stop the rinse pump after XX
S
seconds of continuous rinse signal, conserving
H
rinse agent on door-type dishmachines that fill
through the rinse valve.
Use
/
to choose from 0 to 60 seconds, then
press ENTER to continue.
RINSE DELAY:
00 SEC
This feature delays the operation of the rinse
pump for a selectable time once the rinse signal
is received. The delay time helps to conserve
rinse agent on door-type dishwashers (using with
conveyor machines is not typical for this feature).
Use
/
to choose from 0 to 60 seconds, then
press ENTER to continue.
DETERGENT TYPE:
LIQUID_
SANI RUNS WITH:
RINSE_PUMP
Continue on next page
Page 10 of 52
If you chose CONVEYOR as machine type, you will
see the following menu...
You will be prompted for the rack time. Use a
stop-watch (if available) to clock the time it takes
for one rack to pass through the rinse arm on the
machine. Use
seconds, then press ENTER to continue.
Use SCROLL to choose liquid or dry as the type of detergent, then press
ENTER to continue.
There is also a "SMALL TANK" setting that can be selected for special
applications to enhance dry detergent feed in probe mode (does not apply to
probeless). If SMALL TANK is selected, the detergent feed rate will be more
aggressive when the concentration reading is within 5 Knight units of the
setpoint. Additionally, the detergent alarm (delay) function will be by-passed
when the concentration reading is within 3 Knight units of the setpoint.
Use SCROLL to choose whether you wish to have the sanitizer pump run
(simultaneously) with the rinse pump, or the detergent pump, then press
ENTER to continue.
RACK TIME:
10 SEC
/
to choose from 10 to 255