Pump EcoVISE, EcoP01
Parameters and menu system
Menu: View parameters
Time
Weekday
Weekly Timer program
Actual speed
Actual power consumption
Run time
Motor temperature
Status Digital input 1
Status Digital input 2
Status Analog output
Error code
Software version
24 hours display
Mon = 1 ... Sun = 7
OFF = Timer not activated
Rpm
Watt
Hours
Temp < 100C = Fine
OFF = Input not activated
On = Input activated
Activated / Not activated
1 = Too low DC-voltage
2 = Too high DC-voltage
4 = Too high temperature
5 = Too high motor temperature
10 = Power current error
20 = Overload at startup
64 = Short circuit
97 = Multiple errors
98 = Communication error
8.013
Configuration: Parameters setting
SP1
Speed "ECO"
SP2
Speed "MED"
SP3
Speed "HIGH"
CLoc
Time of day
ti1–9
Weekly timer
t1 on
Day/s, time, speed
t9 off
End time
rEL
Analogue output is open collector type and may be loaded
with max 100mA.
0 = Output off
1 = Output active at speed "ECO"
2 = Output active at speed "MED"
3 = Output active at speed "HIGH"
4 = Output active at error
5 = Output active at high motor temperature
6 = Pump effect limited due to high temperature
d1
Digital input 1
1 = Change to speed "ECO"
2 = Change the speed "MED"
3 = Change to speed "HIGH"
4 = Change to "HIGH" speed for 180 seconds
d2
Digital input 2
1 = Change to speed "ECO"
2 = Change the speed "MED"
3 = Change to speed "HIGH"
4 = Change to "HIGH" speed for 180 seconds
Priti
The time [s] the pump is running at speed "HIGH" at startup
rESEt
Reset factory settings
END
Exit the configuration menu