Herunterladen Diese Seite drucken

MGF Ghibli 17 Gebrauchshandbuch Seite 11

Silent kompressor

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26
2. Drain condensation
Condensation may accumulate in the air outlet filter. Valve at the bottom of the filter gives two
options. In the standard position it drains the filter when it goes to zero bar pressure, turning it
anticlockwise direction it drains immediately (D, Fig. 3 and 4).
3. Open and close the drain valve
The drain valve at the base of the tank (F. Fig. 5) must always be opened when you have
finished using the compressor to expel all air and to allow any condensate to drain out.
NB: When the tank is empty, remember to close the valve again.
1. Replace the oil filler plug/air breather after every 500 hours of operation.
2. If the oil becomes contaminated it will be necessary to drain it.
Remove the filler plug/air filter. Turn the compressor upside down and allow the oil to drain
out. Refill with new SYNTHETIC OIL until the level reaches the middle of the oil sight glass.
MGF synthetic oil is always available by your dealer or the manufacturer.
MGF Silent compressors operating
instruction manual
PERIODICALLY
MGF OIL CHARACTERISTIC: SINCOM 32/E
11

Quicklinks ausblenden:

Werbung

loading