Herunterladen Inhalt Inhalt Diese Seite drucken

DBI SALA UCT-1000 Benutzerhandbuch Seite 6

Für personen zugelassene systeme für den zugang zu und die bergung aus engen räumen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26
INSTALLATION OF WINCHES, SELF-RETRACTING LIFELINES ( SRL's), WORK POSITIONING AND FALL-ARREST
DEVICES NOT MANUFACTURED BY CAPITAL SAFETY GROUP.
Your T-1000 TRIPOD SYSTEM can be used as a support structure for various types of safety devices.
Some of these can mount directly to the anchor point at the top of the tripod head, while others may require an adapter
bracket available from your dealer. Any accessories being used for the hoist MUST BE installed, inspected, maintained
and operated according to the manufactures instructions. All installations MUST BE approved to local standards by a
qualified engineer.
INSPECTION OF EQUIPMENT PRIOR TO USE.
- Check all structural parts for damage: dents, cracked welds bend or crushed tubes. Minor cosmetic damage will not
affect the structural integrity of the hoist, but any seriously damaged parts MUST BE repaired or replaced before using
the hoist.
- Check all hardware ( pins, tri-screws, adjuster screws, nuts, bolts, pulleys, rollers and winch brackets) for damaged
threads, bend, damaged or missing fasteners, loose fasteners. Check all pulleys and rollers for chips, grooves and
excessive wear. Ensure that all pulleys and rollers turn freely.
- Inspect all equipment for missing, damaged or otherwise illegible warning stickers. Any damaged, missing or
otherwise illegible stickers MUST BE replaced before using hoist.
- If you are using Digital Series Winches with your hoist, inspect the winch and cable as outlined in the "maintenance
and inspection" section of the Digital Series Winch operators manual.
- Any additional winches, self-retracting lifelines (SRL's), work positioning or fall-arrest equipment being used with
your T-1000 Tripod System MUST BE installed, inspected, maintained and operated according to the manufactures
instruction.
- Report any problems with the equipment to your supervisor and DO NOT USE the equipment until it has been
repaired or replaced.
INSPECTION / MAINTENANCE SCHEDULE
DAILY ( BEFORE EACH USE) : (SEE ABOVE) INSPECTION OF EQUIPMENT PRIOR TO USE
WEEKLY: Perform a complete visual inspection of equipment as outlined in " Inspection of Equipment Prior to Use".
Clean equipment as required, to thoroughly inspect all welds, labels, pins, fasteners, pulleys, rollers, brackets and parts.
Record all findings on a copy of the "hoist inspection log". If any problems are found with the equipment DO NOT USE
until it has been repaired.
ANNUALLY: Clean unit throuroghly, using a damp cloth and a mild soap solution. Perform a complete visual
inspection as described in section(F) " Inspection of Equipment Prior to Use" Record all findings on a copy of the "hoist
inspection log". If any problems are found with the equipment DO NOT USE until it has been repaired.
T-300/T-1000 TRIPOD SYSTEM
SETUP AND WINCH INSTALLATION INSTRUCTIONS
6

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für DBI SALA UCT-1000

Inhaltsverzeichnis