Herunterladen Inhalt Inhalt Diese Seite drucken

General Specifications - DBI SALA UCT-1000 Benutzerhandbuch

Für personen zugelassene systeme für den zugang zu und die bergung aus engen räumen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26

General specifications:

Rated Capacity (working load)
Max. Allowed Arresting Force
(M.A.F.) rating for retractable
devices or shock absorbers
Proof Load
Leg mounted winch
(outside of leg)
Anchor Point
Weight
Materials & Construction:
General Construction
Tubular Components
Head Assembly
Hardware
Finish
(outer leg & head)
(inner leg)
Plating Specifications
UCT-1000 TRIPOD
SETUP & WINCH INSTALLATION INSTRUCTIONS
The CSG UCT-1000 Tripod combines the quality and user friendly
performance of all CSG Safety Systems Safety equipment with
the economy of the basic tripod. Constructed of lightweight tubular
aluminum with a rugged steel head assembly, the UCT-1000 tripod
can be combined with a variety of pulleys, winches and fall-arrest
devices to meet a wide range of confined space entry / retrieval
and rescue requirements. Plastic sliders between inner and outer
leg tubes provide smooth adjustment and prevent inner tube from
inadvertently pulling out of outer tube. Quick release pins positively
locate components at all adjustment points for tool-less setup and
adjustment
204 Kgs.
@ 11:1 design factor
6kN
22 KN.
22 KN.
48 KN.
31 Kgs.
Aluminum / Welded Steel
6061-T6 Aluminum
H.R. Steel
Gr.5, Gr.8 steel, zinc plated
Green & Black powder coat
Mill Finish
ASTM designated B633-85
type lll, SC2
5
Model includes the following
Item
Description
1
UCT-1000 3m Tripod
Accessories shown in gray but not included
2
Digital 100 Winch
3
Winch Mounting Bracket
4
Top Pulley Ass'y
DESCRIPTION
Application Restrictions:
1. Maximum allowed arresting force (M.A.F.)
rating for retractable devices or shock
absorbers 6kN.
2. Retractable devices or shock absorbers
MUST BE installed and used in accordance
with the manufacture's instructions.
3. All winch or block mounting hardware
MUST BE supplied or approved Capital
Safety Group Ltd.
4. Each installation MUST BE approved to
local standards by a qualified engineer.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für DBI SALA UCT-1000