live electrical parts immersed in protective epoxy resin to provide
total insulation against water damage and electrical shock. The
motor is extremely compact, energy efficient and maintenance-free,
while at the same time producing a powerful continuous output flow.
Choosing the right output for the application
Laguna Statuary Pumps can be used in a wide variety of applica-
tions, and their wide range of output flows at various heights will
accommodate almost every circumstance. What is most important
is to define the needs of the application and ensure the pump will be
adequate to the job. The factors that influence pump capacity include
Head Height, hose and fitting resistance:
Head height: Vertical distance between water surface and water
discharge.
Hose Resistance: For every ten feet (3 m) of hose, add one foot
(30 cm) to the head height.
Fitting Resistance: For every elbow connector, add one foot (30 cm)
to the head height.
Determine the head height first, the vertical distance from water sur-
face to water outlet. To this, add the amount of hose needed to trans-
port the water from pump exhaust to the water outlet. When pipe
fittings are used to go around corners, the resistance to water flow
o
created by a 90
elbow is equivalent to adding one foot (30 cm) per unit.
If the installation requires a 90 cm (3 ft) lift from surface to output,
requires 3 m (10 ft) of hose and one elbow, then the actual head is
150 cm (5 ft).
INSTALLATION
Caution: Disconnect the plug of this and any other submerged
appliance before placing hands in water.
Important: Always use the largest bore hose possible.
Avoid sharp bends in the hose, gentle curves present less resistance
and water flow loss.
ATTACH INPUT/OUTPUT HOSES:
Statuary Pump 1 : accepts a hose on the output only.
Statuary Pumps 2 & 3 : have smooth hose adapters on both input

Werbung