Westfire Insulated chambers
The Westfire UNIQ 37 wood burning stove is lined with heat deflection panels and baffles, these panels are designed
to ensure the maximum efficiency and are an integral part of the clean burn process of the stove. These baffles
should not be removed apart from for cleaning the stove. Any defective panels should be replaced.
Connection to chimney
Westfire UNIQ 37 wood stove has both rear and top flue connector that allows connection to either a masonry
chimney or a prefabricated factory made insulated metal chimney in accordance with the instructions for
"Connection to chimney" given in the instruction booklet.
Commissioning and handover
Ensure loose parts are fitted in accordance with the instructions, page 16. 'Vermiculite fire brick installation
sequence' before handover. Operation of primary and secondary air control sliders must be fully explained.
On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, when
a small fire may be lit and checked to ensure the smoke and fumes are taken from the stove up the chimney and
emitted safely to atmosphere. Do not run at full output for at least 24 hours.
On completion of the installation and commissioning ensure that the operating instructions for the stove are left
with the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be
used on the stove and warn them to use only the recommended fuels for the stove.
Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to
use a fireguard to BS EN 8423:2002 in the presence of children, aged and/or infirm persons.
WESTFIRE · WF37
9
Secondary Air Control Slider
Right = Open / Left = Closed
Primary Air Control slider
Right = Open / Left = Closed
UK