WESTFIREUNIQ 37 WOODSTOVE
UNIQ
37 dimensions
Height
Width
Depth
Closed combustion option
STOVE
PERFORMANCE
& TESTING
Westfire UNIQ 37 have been approved in accordance with EN 13240.
Stove model
UNIQ 37
UNIQ 37 Pedestal
PREPARATORY
WORK
AND SAFETYCHECKS
IMPORTANT
WARNING
This stove must not be installed into a chimney that serves any other heating appliance. There must not be an
extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room.
CHIMNEY
Chimney Connection
Flue Diameter 150mm (175 cm
IMPORTANT:
Wheninstalling the UNIQ 37 wood stoves remove steel retaining bar across flue exit.
Remove bolts and take out bar replace and bolt cast onto collar.
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate
draught so as to clear the products of combustion and prevent smoke problems into the room.
Minimum draft: UNIQ 37 stove has been tested with a draft of 12 Pa. Maximum draft 25 Pa.
Flue gas flow 7.0 g/sec.
Flue gas temperature 303°C. approximately 12 Pa.
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of
the chimney should be satisfactory. Alternatively the calculation procedure given in BS 5854:1980 may be used as
the basis for deciding whether a particular chimney design will provide sufficient draught.
The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building
Regulations Approved Document J.
If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow
fumes into the house. Older properties, especially, may have chimney faults or the cross section may be too large
i.e. more than 160 mm x 160 mm. Remedial action should be taken, if required, seeking expert advice, if necessary.
If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with
Building Regulations Approved Document J.
Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the
stove. If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to
clear any soot falls which may have occurred due to the difference in combustion between the stove and the open
fire.
WESTFIRE · WF37
Weight
90 kg
95 kg
2
)
UNIQ
37
980 mm
505 mm
445 mm
No
Nominal heat output
Wood
7.2 KW
7.2 KW
7
UK
UNIQ
37 Pedestal
1150 mm
505 mm
445 mm
No
Smokeless fuels
N/A
N/A