"SAFETY INPUT"
Functioning mode of safety devices input (terminals 8-10)
DIP 1
ON
OFF
"INPUT PP/OP"
Functioning mode of PP/OP input (terminals 8-11)
ON
DIP 2
OFF
Through the setting of these two dip-switches you can set the SAFETY input (terminals
8-10) as N.C., 8k2, N.O. contact.
DIP3:OFF
DIP4:OFF
DIP 3
DIP3:OFF
DIP4: ON
DIP 4
DIP3: ON
DIP4: ON
DIP3: ON
DIP4: OFF
It is possible to activate the automatic closing function and adjust the automatic closing time.
Proceed as follows:
- Set the DIP-SWITCH 1 = OFF / 2 = OFF / 3 =ON /4 = OFF.
- The DL4 led indicates if the function is on or off and the value of the automatic closing time.
- By pressing the button S2 select one of the following values:
LED on: TCA function deactivated
1 flash: TCA function activated and automatic closing time set on 10 sec.
2 flashes: TCA function activated and automatic closing time set on 30 sec.
3 flashes: TCA function activated and automatic closing time set on 60 sec.
4 flashes: TCA function activated and automatic closing time set on 90 sec.
By setting the Dip-Switches on the following position 1=ON, 2=ON, 3=ON, 4=OFF the control unit
operates in Hold to run mode. The buttons OPEN/CLOSE must be hold down for the entire duration
of the stroke. In this case the PP input works as OPEN input.
In hold to run mode the stroke learning is not possible.
The controls must be positioned so that the operator can check the door for the entire
in compliance with regulations in force.

DIP-SWITCH FUNCTION

The safety input is set on photocell mode, when activated during closing
phase it causes a reversion until the gate is fully open.
The safety input is set on safety edge mode, when activated during opening
and closing phase it causes a partial reversion of the gate (2 seconds).
Input set on OPEN mode: when a sequence of pulses is given, it performs
OPEN-STOP-OPEN-STOP
Input set on Step-by-Step mode: when a sequence of pulses is given,it
performs OPEN-STOP-CLOSE-STOP
with this setting, if the input PP is activated for 3 seconds an opening
command is given, if it is activated for 10 seconds a closing command is
given.
Safety input set as input N.C.
Safety input set as 8k2 input for resistive edge.
Safety input set as N.O. input.
Not used
TCA (AUTOMATIC CLOSING TIME)
HOLD TO RUN FUNCTION
stroke,
9