Installation to Solid Concrete and Cinder Block

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet
ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole
instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
Level and use wall plate as template to mark center
2
of holes. Drill two 5/16" (8 mm) dia. holes to a
minimum depth of 2.5" (64 mm). Insert anchors (B)
in holes flush with wall. Place wall mount (A) over
anchors and secure with wood screws (H). Make
sure wall mount is level, and tighten all fasteners.
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly to
load-bearing concrete.
• Never attach concrete expansion anchors to concrete
covered with plaster, drywall, or other finishing mate-
rial. If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown below. Be sure con-
crete anchors do not pull away from concrete when
tightening screws. If plaster/drywall is thicker than
5/8" (16 mm), custom fasteners must be supplied by
installer. (not evaluated by UL)
INCoRReCT
wall
plate
plaster/
dry wall
concrete
wall
plate
plaster/
dry wall
WARNING
1
Drill holes and insert anchors (B).
2
Place plate (A) over anchors (B) and secure with screws (H).
3
Tighten all fasteners.
CoRReCT
concrete
A
6 of 46
A
H
SOLID CONCRETE
B
WALL PLATE
H
ISSUED: 01-27-08 SHEET #: 095-9283-3 06-12-09
concrete
surface
B
B
CINDER BLOCK
fig. 1.4

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pa740-sPwv250/bk

Inhaltsverzeichnis