Switching off
• Release pressure on the trigger (21). Secure with the trigger lock
lever (20). The trigger is secured and it is impossible to start the
cleaner accidentally.
• Put the switch (5) to OFF position.
• Cut off the water supply.
• Disconnect the device from mains socket.
• Release the trigger lock lever (20) and fully press the trigger (21)
to release all the water under pressure from the device.
• Release the trigger (21) and secure it again with the trigger lock
lever (20).
• Disconnect the connector hose from the device and the water
supply.
The pressure inside the cleaner remains. Do not direct the water
stream onto persons, animals, electric equipment and the
device itself, even after switching the cleaner off.
Ambient temperature during cleaner operation should be
between 5
0
C and 40
0
C.
IMMEDIATE HALT SYSTEM
High pressure cleaner is equipped with immediate halt system
that is motor protection. When the gun handle trigger is
released the motor halts. Pressing the trigger again will start
the motor again.
TRIGGER LOCKING
When temporary break in operation is needed, it is absolutely
necessary to secure the trigger with the trigger lock lever
located on the gun handle to avoid accidental start up.
MOTOR PROTECTION
Electric motor is equipped with safety switch. The safety switch
allows to stop the motor in case of overheating. Before using the
device again, switch it off and wait 20–30 minutes until the high
pressure cleaner cools down.
SPRAYING THE DETERGENT
High pressure cleaner should be used with cleaning agents
designed for such type of devices. Use of other cleaning agents
may have negative impact on safe operation of the tool. Do
not use acids, petrol, kerosene or other flammable liquids as
cleaning agents. Use only domestic-purpose detergents (pH
6–8).
Some surfaces may get damaged by high pressure water stream.
• Make sure the trigger (21) of the gun handle (9) is locked.
• Remove the plug (19) and fill the detergent container (17) with
washing substance prepared in accordance with instructions
specified on the package.
• Rotate the ring (27) of the nozzle (26) on the lance (11) to set it up
for low pressure operation.
• Direct the nozzle (26) onto the surface that you plan to apply
detergent on and release the trigger lock.
• Press the trigger and apply the detergent (when the cleaner is
switched on, the detergent in the container will be sucked and
mixed with water under low pressure).
• Once the detergent is applied, rotate the ring (27) of the nozzle
(26) and proceed with cleaning using high pressure.
Washing substance will be drawn from the detergent container
only when the nozzle is set up to low pressure.
RECOMMENDED CLEANING METHOD
Stage 1: Dissolution of dirt
• Spray the surface with small amount of agent and leave it for short
time.
Stage 2: Removing the dirt
• Use high pressure water stream to remove dissolved dirt (before
it dries up).
• Never bring the nozzle closer than 30 cm away from the
cleaned surface (when in any doubts whether the water
pressure may cause any damage, test the effects on small, not
visible place).
• Never use the cleaner to clean surfaces with easily removable
coating.
• Always move the stream around the cleaned surface. The
water stream must not be directed at the same spot for long
time, because it may damage the surface.
• Before high pressure cleaning always consult the manufacturer
of a product to be cleaned, whether the surface is suitable for
such treatment.
SURFACE CLEANING
The equipment includes 2 brushes for surface cleaning: rotary
brush and floor brush. Rotary brush is designed for cleaning small
horizontal or vertical surfaces. Floor brush is designed for cleaning
of large horizontal surfaces, such as terraces, wooden floors, ceramic
tiles etc.
Rotary brush
• Attach the rotary brush (29) to the gun handle (9) (notice notches
on the connection), press in slightly and rotate by 90
(fig. S).
• You can disassemble the rotary brush by following the installation
procedure in reverse sequence.
Floor brush
The floor brush has integrated detergent container to remove heavy
stains.
• Attach the floor brush (30) to the gun handle (9) (notice notches
on the connection), press in slightly and rotate by 90
• Turn the locking sleeve (31) fully to secure the connection
(fig. T, U).
• Remove the cap (34) and fill the detergent container (32) with
washing substance prepared in accordance with instructions
specified on the package.
• Rotate the application ring (33) in the range 0–MAX to set up
amount of drawn detergent (fig. W).
• You can disassemble the floor brush by following the installation
procedure in reverse sequence.

OPERATION AND MAINTENANCE

Unplug the power cord from the mains socket before
commencing any activities related to installation, adjustment,
repair or maintenance.
CLEANING
• Keep the cleaner body, gun handle, pressure hose and the lance
clean.
• Keeping the nozzle clean is necessary for effective cleaning.
• Clean the nozzle on a regular basis using the rod for nozzle
cleaning.
• Entrust all repairs of the cleaner only to a qualified person. Only
original parts should be used.
• Damaged electric power cord should be replaced by qualified
electrician.
• There are no parts inside the high pressure cleaner that require
user service or maintenance. Take the tool to authorized workshop
when internal parts of the cleaner require repair.
• Thoroughly clean external parts of the device with soft brush and
cloth. Do not use water, solvents or glossing agents.
• Remove all dirt, especially from the motor ventilation holes.
STORAGE
• Disassemble gun handle, pressure hose and cleaner lance and
keep them in the holder for equipment, in a dry place.
• When the water is not fully drained from the device, the device
may be damaged from low temperatures (risk of freezing water
inside the cleaner).
• Store the device in a room protected from low temperatures.
• When unused device will be stored for long time (3 months) in a
room where freezing temperatures may appear, it is recommended
to fill the cleaner pump with a freezing-proof agent (similar to
agents used in cooling systems in cars).
• If the device is not used for a long time, limestone accumulates in
the electric pump, which may cause problems with starting the
device.
• Do not place any objects on the device casing.
• Store the cleaner beyond reach of children.
FILTER CHECK
Check the suction filter on a regular basis to avoid clogging the
device, which can damage the pump.