INSTALLATION

1. Before installation, carefully remove packaging, and make sure not to damage the unit or the connecting
cable. If you find any damage, the unit must not be operated!
2. The unit is intended for use in dry, indoor spaces only!
3. Take out the unit from the box!
4. Fasten the enclosed bases to the bottom of the heater (Figure 3.)! Use 3 small screws for each for that
purpose.
5. Stand the unit on its feet on a hard, flat surface!
6. If wall-mounted design is used, mount the unit without feet on the wall, using the enclosed fittings.
(Figure 4.)
a. Fix the metal holders onto the wall according to the size chart.
b. Hang the appliance on the two upper metal holders and fasten it with two small screws to the lower
ones.
7. The free circulation of warm air must be ensured for proper operation, therefore, please note the
minimum installation distances indicated in Figure 2.!
8. The switches on the unit must be in OFF position!
9. Plug the unit into a standard grounded wall socket. Now the unit is ready for operation!
Caution: Risk of electric shock! Do not attempt to disassemble or modify the unit or its accessories.
In case any part is damaged, immediately power off the unit and seek the assistance of a specialist.
In the event that the power cable should become damaged, it should only be replaced by the
manufacturer, its service facility or similarly qualified personnel.
Meaning of symbol on appliance: Do not cover!
Covering the unit can cause overheating, fire or electric shock!
FEATURES
convector heater for heating the atmosphere of indoor premises • wall mounted or free standing design • 3 heating stages: 750 W / 1250 W / 2000 W • independently switchable turbo fan function •
thermostat control • heating operation display • overheating protection
STRUCTURE (Figure 1)
1. cold air inlet • 2. heated air outlet • 3. TURBO fan air outlet • 4. TURBO fan ON-OFF switch • 5. mode switch with operation indicator light • 6. thermostat • 7. feet • 8. holes for wall mounting • 9.
fittings for wall-mounting
OPERATION
The unit may emit a slight odor when turned on initially, which is not a malfunction. It is harmless and evaporates quickly! Red indicator lamp lights up on the unit, when the appliance is heating.
Using the mode switch you can select from among the following modes:
0:
Switched off
I:
Heating stage I (750W)
II:
Heating stage II (1250W)
III:
Heating stage III (2000W)
Fan operation mode can be switched ON or OFF with the turbofan button (4).
In turbofan operating mode, the inbuilt fan will blow warm air through the grill (3) on the front side of the appliance, to ease the quicker warming of the room.
The thermostat (6) can be used to set the ambient temperature of the room. The appliance will switch on when the ambient air temperature falls below the adjusted. As soon as the set
temperature is reached, the unit will turn off. If you would like to set a higher temperature, turn the thermostat clockwise, if you want to set it lower, then turn it counter clockwise
In the event of overheating, the overheating protection function will switch off the unit, for example when the air inlets and outlets are covered. Power off the unit by unplugging it from the electric
outlet. Allow the appliance to cool (for at least 30 minutes). Check whether the air inlets and outlets are obstructed or not, and clean them if necessary. Switch on the unit again. If the overheating
protection activates again, power off the unit by unplugging it from the electric outlet and contact the service facility.
CLEANING & MAINTENANCE
In order to ensure optimum functioning, the unit may require cleaning at least once a month, depending on the manner of use and degree of contamination.
1. Switch off and power off the unit by unplugging it from the electric outlet before cleaning.
2. Allow the appliance to cool (for at least 30 minutes).
3. Clean the protective grill using a vacuum cleaner equipped with a brush accessory.
4. Use a slightly moistened cloth to clean the unit's exterior. Do not use any aggressive cleaners. Avoid getting water inside of and on the electric components of the appliance!
TROUBLESHOOTING
Malfunction
The unit is not working in heating stages.
Turbo fan is not working.
The overheating protection activates frequently.
Waste equipment must not be collected separately or disposed of with household waste because it may contain components hazardous to the environment or health. Used or waste
equipment may be dropped off free of charge at the point of sale, or at any distributor which sells equipment of identical nature and function. Dispose of product at a facility specializing in
the collection of electronic waste. By doing so, you will protect the environment as well as the health of others and yourself. If you have any questions, contact the local waste
management organization. We shall undertake the tasks pertinent to the manufacturer as prescribed in the relevant regulations and shall bear any associated costs arising.
SPECIFICATIONS
power supply: . . . . . . . . . . . . . 230V / 50 Hz
rated power: . . . . . . . . . . . . . . 750 / 1250 / max. 2000 W
IP protection: . . . . . . . . . . . . . . IP20: Not protected from ingress of water!
size of heater:
. . . . . . . . . . . . . . . . . . . . . . . . standing on the floor: 69 x 45 x 20 cm
. . . . . . . . . . . . . . . . . . . . . . . . mounted on the wall: 69 x 41 x 15 cm
weight: . . . . . . . . . . . . . . . . . . 3,4 kg
length of power cable: . . . . . . . 1,60 m
noise level: . . . . . . . . . . . . . . . 50 dB(A)
Solution
Check the power supply.
Check the thermostat settings.
The overheating protection has activated.
Check the settings of switches.
Clean the appliance.