If the daytime temperature exceeds the set limit, the
alarm contact is activated. For example, if the box breaks
down or does not have enough capacity to suck, this
function will intervene.

10.3 Set Temp offset

Although the temperature sensor is very accurate, it may
be desirable to align it with other measuring equipment.
"Temp offset" allows you to adjust the indication with
+ or - 5.0 °C.
Select "Temp offset" in the TMP menu and press the
PTK.
Overtemp 32.0°
=> Temp offset 0.0°
Night delay
5m
TMP set 26 C
>> NEXT >>
TMP +/- 1.5 C
Turn the PTK to select the desired degree of correction.
Press the PTK to confirm.

10.4 Set night delay

This function allows you to adjust the bridging time
between the moment that the light goes out and the
night temperature is valid. During this period the fan will
not start to run faster.
Select "Night delay" in the TMP menu and press the PTK.
Overtemp 32.0°
=> Temp offset 0.0°
Night delay
5m
TMP set 26 C
>> NEXT >>
TMP +/- 1.5 C
Turn the PTK to select the desired time delay (up to 60
minutes).
Press the PTK to confirm.

10.5 Minimum/maximum temperature values

Select >> NEXT >> on the second page of the TMP
menu and press the PTK.
Overtemp 34.0°
Temp offset 0.0°
Night delay
5m
=> >> NEXT >>
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
Now you can read the minimum/maximum temperature
values. To reset these values, select "Reset min/max" and
press the PTK.
TMP Min
26.2°C
TMP Max 33.6°C
Reset min/max
>> NEXT >>
Select >> NEXT >> and press the PTK to return to the
main screen.

11. Relative Humidity (RH) settings

If an RH sensor is connected to the Clima Control Plus,
you can set the desired air humidity level.
You are in the main screen. Select "RH" and press the
PTK.
TMP = 33.6 °C
=> RH =
66%
BOX =
90%
CO2 = 1112 PPM
Select "Humidity day" to set the desired level during the
day. Press the PTK to confirm.
If you want to completely disable air humidity regulation
during the day, set to "Off"
=> Humidity day 60%
Hum. night
60%
Humidity +/-
3%
>> NEXT >>
Select "Hum. night" to set the desired level during the
night. Press the PTK to confirm.
If you want to completely disable air humidity regulation
during the night, set to "Off".
Humidity day 60%
=> Hum. night
Off
Humidity +/-
3%
>> NEXT >>