8. Setting the Clima Control Plus

The Clima Control Plus is easy to operate with the Push-
and-Turn Knob (PTK). You access the different menus
from the main screen, which displays:
Line 1: current temperature (only displayed when a S-4
or Temp/RH Sensor is connected).
Line 2: current relative humidity level.
Line 3: current fan mode: automatic or manual ("Auto"
or "Man").
Line 4: current CO
level.
2
TMP = 33.6 °C
RH =
66%
=> BOX =
90%
CO2 = 1112 PPM
By pressing the PTK you can access the main menu. An
arrow appears on the left side of the display, allowing
you to select the desired submenu.

9. Setting the fan/box

You access the box menu:
1. after starting the Clima Control Plus;
2. via the main screen.
Select "BOX" and press the PTK.
TMP = 33.6 °C
RH =
66%
=> BOX =
90%
CO2 = 1112 PPM
Select "Select box" and press the PTK.
BOX A/M
Auto
BOX min
10%
BOX max
90%
=> Select box
You access the box menu (fan menu):
Select box
=> Custom
Lemmens
Torin
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
Select the brand of your box by turning the PTK. Press
the PTK to confirm and continue with section 9.2.
If your brand does not show, choose the "Custom"
option. Press the PTK to confirm and to access the next
screen.

9.1 Custom menu

Set box to desired
minimum speed.
Push to proceed.
The fan is not running or very slowly. Slowly turn the PTK
until the fan runs at 10% of its maximum speed. You set
this as the minimum speed.
Confirm by pressing the PTK. You will enter the next
screen:
Set box to desired
maximum speed.
Push to proceed.
■■■■■■■■■
Now, adjust the fan to the desired maximum speed,
which is 90% of the maximum capacity. First, let the fan
run at maximum speed and then slightly turn back the
PTK until the fan runs at 90% of its capacity.
Press the PTK to confirm.
The box is now
adjusted.
Push button to
continue.
Press the PTK again to access the next screen:
Set the time between
changing the power
level of the box.
4s
Turn until the desired interval is reached (up to 250
seconds).
For small spaces we recommend to select a short
interval (5-10 seconds), and for large spaces a somewhat
longer interval.
18