Technical Data

Combi Stratified Tank
KWS 500 - 800 - 1000 - 1500 R
G1"
G1"
Solar Vorlauf 1" IG
Solar flow 1'' inner
thread
Solar Vorlauf 1" IG
Solar Rücklauf 1" IG
Solar return flow 1''
Solar Rücklauf 1" IG
inner thread
cOnnEcTIOn Of HEATInG SOuRcE TO BuffER STORAGE
ØD (mm)
A (mm)
B (mm)
When connecting the respective heating source, the relevant manufacturer's specifications must be observed! The responsible plumber must connect
ØD (mm)
A (mm)
B (mm)
650
220
220
the connection of the heating to the connections that are freely available (6/4" internal thread), depending on the type of heating (radiators, floor or panel
790
260
375
heating).
650
790
220
310
220
425
790
260
375
950
310
425
1000
790
380
310
425
480
950
310
425
Vo-
1000
380
480
Type
lume
H
Litres
KWS 500
500
1640
KWS 800
800
1686
KWS 1000
1000
2036
KWS 1500
1500
2142
misprints and technical changes reserved.
KOMBI-SCHICHTSPEICHER
KOMBI-SCHICHTSPEICHER
6/4" IG oder Entlüftung
6/4'' inner thread or ventilation
6/4" IG oder Entlüftung
D
D
C (mm)
E (mm)
F (mm)
G (mm)
C (mm)
E (mm)
F (mm)
G (mm)
620
1010
1390
220
630
1030
1430
255
620
745
1250
1010
1390
1710
255
220
630
1030
1430
255
745
1250
1710
310
745
825
1250
1350
1760
1710
380
255
745
1250
1710
310
Dimensions in mm
825
1350
1760
380
ØD
A
B
C
650
220
335
620
790
260
368
630
790
310
418
745
1000
380
470
825
6/4" IG
6/4" IG
6/4" IG
6/4" IG
6/4" IG
6/4" IG
6/4" IG
6/4" IG
6/4" IG
6/4" IG
Filling
It is bindingly necessary to fill or pressurise the inner corrugated tube
first and then the buffer tank (hot water area).
Emptying
When emptying the system, the buffer tank (hot water area) must be
depressurised in the first step and then the corrugated tube in the se-
cond step.
The corrugated tube may be destroyed in the case of non-compli-
ance with the filling or emptying procedure!
*According to DIn 1988-2, you are required to install a drinking water
filter in systems with metal pipework. As per DIN 1988, we also recom-
mend the installation of a drinking water filter when using plastic pipes
to prevent contaminants from entering the drinking water system.
for any claims for warranty (warranty 3 years), the installation of a ser-
vice water expansion vessel in the hot water line must be confirmed
using the relevant invoice.
J (mm)
K (mm)
L (mm)
J (mm)
K (mm)
L (mm)
290
760
1390
325
820
1455
325
290
955
760
1390
1805
325
820
1455
325
820
1710
325
400
1120
955
1805
1760
325
820
1710
400
1120
1760
E
F
G
J
K
1010
1390
220
290
740
1030
1430
255
318
813
1250
1710
255
318
948
1350
1760
306
370
910
Warmwasser 1"IG
Hot water 1'' AG (high-grade steel*)
Warmwasser 1"IG
Wellrohr
Wellrohr
corrugated tube
Fühlerprofile
Fühlerprofile
Sensor profiles
Solarregister
Solar register
Solarregister
Thermische Schichteinrichtung Heizungsrücklauf
Thermal layers
Thermische Schichteinrichtung Heizungsrücklauf
Heating return flow
Kaltwasser 1" IG
cold water 1'' AG (high-grade steel*)
Kaltwasser 1" IG
Kippmaß Heizfläche Wellrohr
Wellrohr
Solar (m²)
(m²)
Liter
Kippmaß Heizfläche Wellrohr
Wellrohr
1750
1,8
4,3
19
Solar (m²)
(m²)
Liter
1750
2,4
6,3
28
2070
1750
1,8
3
4,3
8,1
19
36
1750
2,4
6,3
28
2270
3
9,9
44
2070
2270
3,6
3
10,6
8,1
47
36
2270
3
9,9
44
tip-
corruga-
solar flue
2270
3,6
10,6
47
ping
ted tube
surface
L
height
m
2
1425
1750
5,0
1443
1750
6,5
1793
2070
7,7
1826
2270
7,5
fitting
corrugated
length
tube litres
m
coupling
2
1,8
25
700
2,5
33
840
3,1
39
840
3,5
39
1050