Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - vidaXL 90291 Bedienungs- Und Sicherheitshinweise

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 93
stop immediately and have it repaired.
6 Caution: Owing to the complexity of the cases covered,
the instructions for installation, use, and maintenance
contained in this manual do not attempt to examine all the
5.3
Troubleshooting
Symptoms
Probable Cause
Suction air leak.
Pump will
not prime.
No water in the pump.
Closed valves or blocked lines.
Motor has no power supply.
Motor will
not run.
Pump jammed.
Dirty filter.
Dirty skimmer and pump strainer.
Low flow.
Suction air leak.
Closed valve or blocked line.
Low or incorrect voltage.
Motor
runs hot.
Installed in direct sunlight.
Poor ventilation.
Bad bearing.
Air leak in suction.
Noise
Suction blockage.
pump
operation.
Disturbance in impeller.
Cavitation
Motor not connected properly.
Low incoming voltage.
Motor
overload
cuts out.
Over load due to binding in pump
or wrong size impeller.

6 Technical specifications

Rated voltage
Rated input power
92 | 90291
What to do
Make sure that the water level in the suction point is correct. Ensure that
baskets and strainers are free of debris. Tighten all fittings/unions on the
suction side of the pump, remove and replace mechanical seal.
Make sure that the filter tank if full.
Open all valves in the system, clean the skimmer and pump basket, check
the pump impeller for blockage.
Check that all electrical switches are on. Ensure that the circuit breakers are
properly set. Check if the timer is set properly. Check the motor wiring at
terminals.
With the power switched off, turn the pump shaft (should spin freely).
Backwash or clean the cartridge.
Clean the skimmer and pump strainer.
See 1
See 1
Supply to be corrected by an electrician. Motor running hot to the touch is
normal. Thermal overload protector will function to turn them off if there is
an overload or excessive high temperature problem.
Shield from weather.
Do not tightly cover or enclose the motor.
Have an electrician replace it.
See 1
Locate and clean the blockage.
Contact supplier.
Improve the suction, reduce the suction lift, reduce the number of fittings,
increase the pipe size, increase the discharge pressure, and reduce the flow
by throttling the discharge valve.
Have an electrician check the wiring.
The voltage on motors should be no more than 6% above or below the
nameplate voltage. Have an electrician check the voltage. Ensure that the
pump is not running on an extension cord. Report the low power supply to
authorities.
Contact supplier.
220-240V~, 50Hz
400W
possible and imaginable cases of service and maintenance. If
supplementary instructions are required or if special
problems arise, do not hesitate to contact the distributor or
to address the manufacturer of the pump directly.
Protective class
Total head
Maximum liquid temperature
IPX5
8.5 m
40 °C

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für vidaXL 90291

Inhaltsverzeichnis