Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not
correspond with temperature set
Temperature regulation not possible - thermo cartridge calcified
Instantaneous heater didn't work
with thermostat
Shower or spout dripping
English
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or
leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- Filters are dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't
removed
- Dirt or sedimentation on valve seat,
shut-off unit damaged
Assembly (see page 12)
Remedy
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filter in front of the mixer
and on the MTC-thermo cartridge
- Clean filter seal between shower
and hose
- Clean backflow preventers,
exchange if necessary
- Adjust thermostat
- Increase hot water temperature to
42 ºC to 65 ºC
- Exchange thermo cartridge
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
- Clean or exchange shut-off unit
5