Herunterladen Inhalt Inhalt Diese Seite drucken

WimTec SanTec PROOF W6 Montage- Und Bedienungsanleitung Seite 24

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
Assembly
7
10
7.
Remove the sealing plug and mount the outlet pipe.
8. Feed the power connection cable (2 x 0.5 mm
disinfection (2 x 0.5 mm
(art. no. 117 899 , 113 792).
Attention: The power supply must not be installed in the flush-mount set!
9.
Connect the magnetic valve to the electronics module.
For models with thermal disinfection: Connect the lower magnetic valve (red dot) to the
electronics module (cable with red marking).
10.
Connect the power cables to the electronics module. Make sure to use the correct polarity
(+/-). Then turn on the power supply. (This will cause the safety locking mechanism of the
magnetic valve to activate.)
11.
Attach the mounting frame using the 4 screws supplied. Make sure that the cable connections
remain intact and the cables are not crimped. When tightening the screws, ensure that the
mounting frame does not get warped.
24
Wall tap control
PROOF W6
8
11
2
) into the flush-mount set and connect it/them to the power supply
SanTec OCEAN W6
9
) and, if applicable, the control line for thermal
2