LED's ( 0=off, 1=on)
in point position
8 7 6 5 4 3 2 1
0 0 0 0 0 0 0 1
0 0 0 0 0 0 1 0
0 0 0 0 0 0 1 1
0 0 0 0 0 1 0 0
0 0 0 0 0 1 0 1
GB
0 0 0 0 0 1 1 0
0 0 0 0 0 1 1 1
0 0 0 0 1 0 0 0
0 0 0 0 1 0 0 1
0 0 0 0 1 0 1 0
1 0 0 0 0 0 0 1
1 0 0 0 0 0 1 0
1 0 0 0 0 0 1 1
1 0 0 0 0 1 0 0
1 0 0 0 0 1 0 1
1 0 0 0 0 1 1 0
Troubleshooting:
The LEDs fail to light up.
If the LED fails to light up when a switching track is actuated check if voltage has been indeed connected to the
common pole (+) of the feedback detector e.g. from the track.
LEDs light up continuously and are not reset.
After the cyclical read-out of the feedback information (polling) through the interface the LEDs are extinguished
again. This means that when a switching track is not continuously actuated mechanically or has remained stuck by
mistake the LED will go out after a short time. This reaction time differs in length but should be less than one second
depending on the software setting. However this process functions only if the interface is connected correctly and
the PC software Rocomotion is started and correctly set (feedback detectors must be confi gured).
The feedback information is not displayed by the PC software.
If the LEDs are reset after the actuation of switching tracks it is likely to be a setting problem in the software. Verify
the address allocations and the connection display to the interface.
The address is incorrect.
You will have to re-program the feedback detector. When doing so please note that the addresses must be in as-
cending order without gaps. The electrical confi guration is immaterial. Please note the information in the software
description when programming the addresses.

Technical data

8 opto-decoupled DC-isolated inputs (in 2 groups)
8 red LEDs
2 RJ45 connectors for feedback bus
Supply voltage:
Maximum power consumption:
Dimensions:
6
6
8010787920 XII_2005.indd 6
Initialisation
Every feedback module must have its own address by way
Adresse
of which it is addressed in the system from the interface. The
preset module address (default address) is 01. Once the bus
1
cable is plugged in (assuming connected and power-supplied
2
components such as amplifi ers, master mouse and interface)
3
a self-test is performed with each feedback module in that
the eight LEDs
4
are activated in running- light fashion. The address is subse-
5
quently displayed encoded according to the following model
6
for approximately 1 second.
7
8
All feedback module addresses must be conti-
9
nuously assigned in ascending order starting at 1!
10
The device addresses of the feedback modules are
11
retained in the de-energised state even after the
12
system has been switched off.
Within a minute following switching on the address
13
can be changed via the software: See description
14
concerning the software Rocomotion with inter-
15
face 10785!
16
12V (provided by the interface 10785)
approximately 40 mA (all LED's illuminated)
approximately 9 x 6.5 x 2.5 cm
22.12.2005 10:00:11