Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Fully open the fitting by turning the Blue
- The cooler will be filled.
- If water flows out of the spout close faucet by turning the
®
Blue
handle.
If the Blue
®
handle is flashing red and E4 or E6 appears in
the display, the fitting and cooler must be synchronised
as follows, see Fig. [8]:
• Press and hold the
and
flashes in the display.
• Press the
button until SE stops flashing.
• Release the
button, C- flashes in the display.
• Keep pressing the
or
button until H- flashes in the
display.
• Press the
button until H- stops flashing.
®
• Blue
handle synchronisation starts; HC appears in the
®
display and the Blue
handle lights up red.
®
• As soon as the Blue
handle lights up green, open the fitting
®
fully by turning the Blue
handle.
®
• As soon as the Blue
handle briefly flashes green, close the
®
fitting by turning the Blue
handle, HC flashes in the display.
• Confirm the setting by pressing the
appears.
• Release the
button.
The remaining filter capacity is displayed.
Commissioning
Control, see fold-out page II, Fig. [8].
The buttons have the following functions:
Filter replacement reset
Filter size selection
Carbonate hardness adjustment
Display, see fold-out page II, Fig. [8].
In the inactive state, the remaining filter capacity is displayed
in percent.
Set the temperature of the cooled water on the cooler, see
fold-out page II, Fig. [9].
Set the filter size, see Fig. [10].
button for filter size selection:
• Press and hold
button once until the currently setted
value (e. g. F1) flashes in the display
• Press the
button and select the required value appears
- F1:
600 liters
40 404 000
- F2:
1,500 liters
40 430 000
- F3:
3,000 liters
40 412 000
- F4:
600 liters
40 404 001
- F5:
1,500 liters
40 430 001
- F6:
3,000 liters
40 412 001
- F7:
600 liters
40 691 001 (Magnesium)
- F8:
3.000 liters
40 547 001 (Activ carbon)
• Press and hold the
button until the required value stops
flashing
• Release the
button:
The remaining filter capacity is displayed.
Note: The various filter cartridges can be ordered at
www.grohe.com.
Set carbonate hardness at filter head, see Fig. [10].
The relevant water supplier can provide information on the
carbonate hardness.
Set carbonate hardness at bypass setting of filter head to local
conditions, see table column A on fold-out page II.
5
®
handle
buttons simultaneously until SE
button longer, HC
Display and setting of carbonate hardness on cooler, see
table column B on fold-out page II and Fig. [8].
button for carbonate hardness adjustment:
• Press and hold the
button once until the currently setted
value (e. g. C3) flashes in the display
• Press the
button and select the required value:
- C4: carbonate hardness
- Factory setting:
C3: carbonate hardness
- C2: carbonate hardness
- C1: carbonate hardness
• Press and hold the
button until the setted value stops
flashing
• Release the
button.
The remaining filter capacity is displayed.
The liter capacity of the cartridge varies according to the water
hardness set and the size of the cartridge, see table on
fold-out page II.
The cooler of the GROHE Blue
the 600 liter filter cartridge (Prod no.: 40 404) at the factory.
For operation with the 3,000 liter filter cartridge (Prod. no.: 40 412)
or 1,500 liter filter cartridge (Prod. no.: 40 430), the cooler must be
adapted.
The fitting with cooler is now fully installed and ready for
operation.

Maintenance

Resetting filter capacity after changing filter cartridge, see
fold-out page II, Fig. [8].
button for filter replacement reset:
• Press and hold
button until rF flashes in the display
• Release the
button until rF stops flashing
• Release the
button:
The remaining filter capacity is reset and then displayed
again.
Restore factory settings, see Fig. [8].
Reset
buttons to factory settings:
• Press and hold the
buttons simultaneously until PA
appears in the display
• Release the
button pressed until PA starts flashing,
HC lights up and fitting and cooler must be synchronised
with one another
• Blue
®
handle synchronisation starts; HC appears in the
display and the Blue
®
handle lights up red.
• As soon as the Blue
®
handle lights up green, open the fitting
fully by turning the Blue
®
handle.
• As soon as the Blue
®
handle briefly flashes green, close the
fitting by turning the Blue
®
handle, HC flashes in the display.
• Confirm the setting by pressing the
appears.
• Release the
button.
The remaining filter capacity is displayed.
Important:
Risk of damage!
Always disconnect the power supply before carrying out
maintenance work on the system. The plug-in connector
can then be disconnected, see fold-out page II, Figs. [6]
and [7].
Inspect and clean all components and replace if necessary.
Assemble in reverse order.
9
(bypass 3)
10 - 24
(bypass 2)
25 - 29
(bypass1)
30
(bypass 0)
®
fitting is set for operation with
button longer, HC

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Blue chilled 40 693

Inhaltsverzeichnis