12. Troubleshooting
Fault
Cause
Unit won't heat up Faulty magnetic valve
Faulty heating element
STB triggered
Water output sub-
Scale / soiling
stantially reduced
Unit will nottop up Faulty magnetic valve
Faulty electrical control
Water flows from
STB (steam) has triggered
the steam pipe
Outlet won't close
Scale residues under tap
seal
Damaged tap seal
20
|KA

13. Maintenance

» Remedy
Check magnetic value oper-
ation, replace if necessary.
Check heating element, re-

13.1 Service mode

place if necessary.
Remove cause of error,
The unit may be placed in service mode for easier access. The
press STB.
Descale unit.
Check magnetic valve oper-
ation, replace if necessary.
Check connections to
electronic sub-assembly,
replace if necessary.
Eliminate reason for fault
e.g. descale unit, press STB.
Remove and clean if neces-
sary.
Replace tap seal.
1 Heating flange
2 Service clip
» Loosen service clip.
» Remove unit from the wall from the bottom, insert service

13.2 Descaling the unit

The unit can be descaled after demounting the heating element.

13.3 Drain funnel

The drain funnel may dry out from time to time. Top up if neces-
sary (to prevent odour).
Disconnect unit all-pole from the mains when working
on it!
following steps are necessary for this purpose:
» Disconnect electricity and water supply.
» Remove lower unit cover by loosening the screws.
» The unit must be emptied through the drain valve (see chap-
ter "Installation / Water connection").
2
clip in the strap and secure with a screwdriver.