Power should only be switched on once the units have been installed
and live parts cannot be touched.
Danger!
Danger to life from touching live parts.
Always keep switching cabinets locked.
Do not undertake any work on live parts.
Change loose connections and any damaged, scorched or burnt
through cables immediately. Only undertake any work when the
main switch has been disconnected and shut off.
Ensure that no cables are trapped or squashed. Ensure that the
cables are laid in such a way that they do not lead to any trip
hazards or can be damaged.
All work may only be undertaken by skilled personnel who have
been instructed and trained on the system.
Only authorised personnel with a key or tool are allowed to
access the switching cabinets.
We recommend that the power supply is fitted with an FI safety
switch in damp areas.
Power should only be switched on once the equipment has been
installed and live parts cannot be touched.
If the switching amplifier and FLUXTRONIC are located in an
explosion-risk zone (zone 1) only approved switching amplifiers
(category 2) should be used.
If the switching amplifier is located outside of the explosion-
risk area and the FLUXTRONIC in the explosion-risk area (zone
1) only approved switching amplifiers with a control circuit (category
2) should be used.
Attachment FLUXTRONIC Automatic Mode
33 / 84