8. Display
Shows the set % humidity from 35% to 85% or auto start/stop time (0-24) while setting, then
shows the actual (+- 5% accuracy) room % humidity level in a range of 30% RH (relative humidity)
to 90%RH (relative humidity).
Error codes and protection codes
AS – humidity sensor error – unplug the unit and plug it back in. If error repeats, call for service.
ES – temperature sensor error – unplug the unit and plug it back in. If error repeats, call for service.
P1 – unit is defrosting – allow the unit time to automatically defrost. The protection will clear after
the unit self defrosts.
P2 – bucket is full or bucket is not in right position – empty the bucket and replace it in the right
position.
E3 – unit malfunction – unplug the unit and plug it back in. If error repeats, call for service.

Other features

Bucket full light
• glows when the bucket is ready to be emptied, or when the bucket is removed or not replaced
in the proper position.
Auto shut off
• the dehumidifier shuts off when the bucket is full, or when the bucket is removed or not replaced
in the proper position. When the setting humidity is reached, the unit will be shut off automatically.
For some models, the fan motor will continue operating.
Auto defrost
• when frost builds up on the evaporator coils, the compressor will cycle off and the fan will con-
tinue to run until the frost disappears.
• Note: when auto defrosting operation, the unit may make a voice of refrigerant flowing, it is normal.
• Wait 3 minutes before resuming operation – after the unit has stopped, it can not be restart opera-
tion in the first 3 minutes. This is to protect the unit. Operation will automatically start after 3 minutes.
Smart dehumidifying mode
• at smart dehumidifying mode, the unit will automatically control room humidity in a comfortable
range 45%-55% according to the room temperature. The humidity setting function will be invalid.
Auto – restart
• if the unit breaks off unexpectedly due to the power cut, it will restart with the previous function
setting automatically when the power resumes.
Setting the timer
• When the unit is on, first press the Timer button, the Timer OFF indicator light illuminates. It
indicates the Auto Stop program is initiated. Press it again the Time ON indicator light illuminates.
It indicates the Auto Start is initiated.
• When the unit is off, first press the Timer button, the TIMER ON indicator light illuminates. It
indicates the Auto Start program is initiated. Press it again the Time OFF indicator light illuminates.
It indicates the Auto Stop is initiated.
• Press or hold the UP or DOWN pad to change the Auto time by 0,5 hour increments, up to
10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining
until start.