If any of these occur, the oil must be changed
at once.
Remedy: Install the compressor in a warm,
dry room, or use smaller compressor.
•
Check the oil level weekly, and top up
with appropriate oil if necessary.
•
Never mix oil of different types or quality
grades together.
6.4.2
Oil-Level contrl on units with oil
DIP-Stick
Extract oil dip stick
The oil level must be between the notches on
the oil dip stick
6.4.3
Oil-Level control l on units with
Oil–EYE
The oil level shown in the oil Oil-Eye must be
within the circle.
6.4.4
Recommended Oil
Original special oil for the compressor
EFA-Spezialöl 1,0 l Art. Nr. 001 365 637
EFA-Spezialöl 5,0 l Art. Nr. 001 365 636
6.5 Oil change
Hot - Oil
Compressor oil can be very hot, and there is a
danger of being scalded. Take all necessary
care with this work.
6.5.1
Procedure
•
Oil quantity: see technical data
•
Let off the used oil at normal operating
temperature
•
Close the oil outlet screw
•
Fill the fresh oil in at the spout
BA-NR.: [001 580 558]
Compressor
[001 606 885]]
•
Dispose of the used oil in an environmen-
tally responsible manner,
6.6 Air suction filter
6.6.1
Control intervals
Depend on the type your unit is fitted accord-
ingly with one or other of the following air fil-
ter:
6.7 Pressure Switch
Operating instructions for the pressure switch
are enclosed with it. Note the maximum val-
ues when adjusting the pressure witch.
16/25
EN
Stand/Version
05/2014