3 Starting Up and operational
safety
Compressor block and the pipes
can be very hot during and after
Operation.
Rotating wheels, belts and fan
blades can cause serious injury.
Commissioning is therefore only
when attached Admissible belt
guard or closed housing
4 Handling
4.1 Switching on
Check the Starter switch-it must be set at
the "0" position.
Check the oil level
Switch the master switch on or plug in.
Set the starter switch to the "1" position,
and the machine is now ready to operat-
ed.
The compressor start automatically when
compressed air is drawn off and the
pressure in the storage tanks falls bellow
a pre-set level. It is therefore possible
that the compressor does not start up as
soon as it is switched on, and that it only
switches off after a certain time delay
(see pressure switch).
The compressor stops automatically as
soon as full pressure is attained.

4.2 Switching off

Avoid causing damage to the electric motor,
and only ever switch the machine off at the
starter switch. Do not use the lockable master
switch for this purpose and never pull the
main plug out when the machine is switched
off.
Set the starter switch to the "0" position.
The motor and the sompressor will now
switch off.
The compressed air line between the
compressor and the storage tank will let
the air off automatically, so as to ensure
that the compressor can start up again
with no load against it.
Pressure in the storage tank will be main-
tained
BA-NR.: [001 580 558]
Compressor
[001 606 885]]
Turn the lockable master switch off or plug off.
4.3 Protecting the motor from exces-
sive temperature
Units with automatic pressure switch can start
by themselves once the unit has cooled down.
This means people are at risk. For this reason
once the motor protection has.
Been triggered off the unit machine or to high
an ambient temperature causes an excessive-
ly high temperature in the electric motor, the
motor cut-out on the compressor will automat-
ically shut the machine down.
The following steps must be taken when the
cut-out has been triggered off:
Switch the machine off at the starter
switch
Discover and rectify the cause of the mal-
function
Wait another 15 to 20 minutes for the
motor to cool down
Reverse the motor protection switch on
units with the manual motor protection
Restart the machine
5 Transport, Installation and
Connection
5.1 Transport
When lifting and transporting the compressor
Let the air off from the machine
Undo the connections
Secure loose or moving parts
Adhere to local safety regulations
Only ever use suitable lifting gear wih
sufficient lifting capacity.
5.2 Installation
Set the compressor on a cool, dry place.
13/25
The stay below a suspendes load is
strictly prohibited! Falling load may
cause serious injury
Improper lifting causes damage, Lift
the compressor, therefore only the
provided on parts. Lift compressor
never to the cladding or the com-
pressor block.