Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Regulations To Be Observed; Chimney Design - Olsberg Palena-Compact Anleitung

Kaminofen, raumluftunabhängig
Vorschau ausblenden Andere Handbücher für Palena-Compact:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Stove Palena-Compact
Instruction
Contents
Foreword ................................................. Page
Technical Data ..................................................... 9
Regulations to be observed ............................... 9
Chimney design ................................................... 9
Combustion air supply ..................................... 10
Installing the stove .............................................10
Assembly sequence .......................................... 10
Operation ...................................................... 10-12
Cleaning ............................................................. 13
What to do if? .................................................... 13
Foreword
This stove is a top quality modern heating technology
product.
A large degree of user comfort and high fuel utilisa-
tion enable it to be used as high quality space heat-
ing, without having to do without the cosy atmos-
phere of an open fire.
Proper installation and correct handling and care are
indispensable for problem-free operation and a long
service life. Please therefore observe all the infor-
mation given in these instructions. We are convinced
that you will then derive a great deal of pleasure from
this stove.
Please keep these instructions in a safe place so that
you can read through them at the start of each heat-
ing period.
Should you find any transport damage, please report
it to your supplier immediately as otherwise it will not
be possible to correct the damage free of charge.

Technical Data

- Nominal thermal output
- Height to middle of the connector pipe with
the connection is at the back
- Height to top edge of connector pipe with
the connection at the top
- Connection pipe
- max. Weight
- Connection combustion air
- Operating Mode
GB
9
[kW]
5,0
[mm]
1088
[mm]
1228
∅ 150
[mm]
[kg]
130
∅ 125
[mm]
Intermitting burning
Page 9 - 13

Regulations to be observed

Local and building law regulations
The stove must be installed by a professional
and connected to the chimney.The specific na-
tional regulations for safe installation of the con-
nector must be complied with.
The stove complies with EN 13240.
The heating stove's fire door is self-closing; it is
therefore approved for connection to chimneys with
multiple connections.
It must be ensured that adequate combustion air is
available. If necessary, it must be fed from the out-
side.Please contact your local master chimney
sweep, specialist trader or skilled tradesman for pro-
fessional advice.

Chimney design

The chimney is designed to EN 13384-2 or to the
specific national regulations.
The chimney must comply with the temperature class
T400.
Necessary data
:
Closed operation:
Nominal thermal output
Waste air mass flow rate
Waste air temperature
Minimum delivery pressure
at nominal thermal output
23/575
[kW]
5,0
[g/s]
5,5
[°C]
268
[Pa]
12
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis