Program
Function
no.
P14
ALARM 1
For P12 = 1 only
Switch-off time when pulsating alarm is activated in 0.1 s (1-99) [10]
P15
ALARM 1
Activation delay in seconds (0...999) [2]
P16
ALARM 1
Deactivation delay in seconds (0...999) [5]
P17
ALARM 2
(0) deactivated (1) normally open contact (NO), [1] (2) normally closed contact
(NC)
P18
ALARM 2
as P11, [70]
(When this value is exceeded, the displayed value will flash, as an additional
warning).
P19
ALARM 2
as P12, [0]
P20
ALARM2
as P13, [5]
P21
ALARM 2
as P14, [5]
P22
ALARM 2
as P15 [2]
P23
ALARM 2
as P16 [5]
P24
ALARM 2
(0) non-resting, [0] (1) resting (switch off to enable)
P25
Analogue output
(0) deactivate, [0] (1) proportional to wind speed
(2) proportional to wind direction
P26
Wind speed / direction value corresponding to the analogue output value of 20
mA [120]
P27
Timeout of radio transmission
For P02 = 2 and P03 = 1 only
Time in seconds (5 ... 99) [12]
NOTE: The Timeout should not be less than 9 seconds if the meter is battery
powered
P28
Alarm status when timeout is activated
(0) no alarm (1) ALARM 1 active (2) ALARM 2 active, [2]