Herunterladen Diese Seite drucken

Very Important - Eccotemp CEI-12 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für CEI-12:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
Installation Instructions Continued...
6. Control Device for the Evacuation of Gases (T.T.B.)
6.1. The T.T.B. safety element that is fitted to the water heaters ensures that combustion products
are evacuated properly and should, therefore, not be deactivated and uncontrolled interventions
should not be performed on it. In case of disturbances in the evacuation of combustion products the
device interrupts the gas supply to the burner.
6.2. If the T.T.B. device is activated once the water heater is turned on, revise the burnt gas outlet
by checking the evacuation with a cooled mirror with running water, or any other measuring device
approved for this purpose.
6.3. In case of damage, use only original spare parts as the T.T.B. device may not work properly
otherwise.
6.4. The T.T.B. device should be replaced by experts as follows:
- Remove the defective T.T.B. device by loosening the two screws holding it together.
- Remove the thermocouple.
- Insert a new original thermocouple.
- Attach the T.T.B. device to the smoke box without forcing the screws.
- Check it is working properly.

Very Important

In the premises where the water heater is located, do not forget to open the air inlet and, where
appropriate, the air outlet as per the requirements of the GAS Installations Regulations. To maintain
a clean Environment, remember to dispose of used batteries in containers prepared for collecting
these products. Not doing so can potentially create a hazardous situation.
18
Product Support: Eccotemp.com/help-desk
Shop Online: Eccotemp.com/products
Store Locator: Eccotemp.com/locator

Werbung

loading

Verwandte Produkte für Eccotemp CEI-12