Mounting the Water Heater
4 holes 121.92 mm
deep 609.6 mm
Installing the water heater
Venting
The installation of venting must comply
with national codes, local codes, and the
vent manufacturer's instructions.
The water heater must be vented
to the indoors as described in these
instructions. DO NOT connect this water
heater to an existing Vent or Chimney,
it must be vented separately from all
other appliances.
Use a vent pipe with an anti-
disconnection structure.
The use of a High Temperature Silicone
(260' c) may be required to seal vent
connections. To prevent accidental gas
exhaust leakage, apply a 1/4" wide bead
approximately 1/4" from the end and
another bead against the joint side of
the stop bead.
Follow vent manufacturer's installation
instructions.
The unit can be vented vertically.
Vent pipe runs must be adequately
supported along vertical runs.
14
1706.88 mm
Make sure the location of the appliance allows for easy access and
operation.
In case of dry wall or concrete wall use dry wall anchors or lag bolts.
Have a receptacle with ground terminal near the water heater. The
length of the power supply cord is 1524 millimeters.
Drill the holes as per the sizes in the figure to the left, put 2
expansion screws into the top holes, and 2 rubber screws into the
bottom holes.
Hang up the water heater unit, tighten the expansion screws, and
put 2 wood thread screws into the bottom holes.
1706.88 mm
Product Support: Eccotemp.com/help-desk
CAUTION: Reinforcement of the wall is required in case the
wall is not strong enough to hold the appliance.
DANGER: Failure to install the vent adapter and
properly vent the water heater to the outdoors as outlined
in the Venting section of this manual will result in unsafe
operation of the water heater causing death, serious injury,
explosion, or fire. To avoid the risk of fire, explosion,or
asphyxiation from carbon monoxide, NEVER operate the
water heater unless it is properly vented and has adequate
air supply for proper operation as outlined in the Venting
section of this manual.
VERTICAL
INSTALLATION
Please refer to
local installation
professional
or venting
manufacturer:
The installation hole
in the wall needs to
be sealed by fire-
retardant material or
wall thimble, making
sure the water heater
is tight and will not
come off.