CHARGE PROGRAM
If voltage selection in STEP 1 matches the expected battery voltage and there are no connection errors as described in
STEP 2, then fully automatic operation starts from STEP 3.
STEP 1
1a
Voltage
Selection
12.8V
&
BMS reset
STEP 2
1a
Protection
12.8V
Low Volt
16V
battery
8
TEST
STEP 3
TEST LEDs
6 : GREEN
TEST
7 : YELLOW
before
8 : RED
charge
8
TEST
6
Bms
Bms
LED #1a / 1b:
voltage.
1b
Changing voltage selection: Disconnect charger from battery. Push and release the
2
SELECT pushbutton. The mode selection changes when the button is released.
SAVE (#3), CHARGE (#4) and TEST (#6, 7, 8) LEDs flash twice to confirm selection is in
16V
memory.
LED #1a => 12.8V
LED #1b => 16V
NOTE: Selection remains even if AC power is lost.
AUTOMATIC BMS RESET:
that protects against deep discharge.
confirm the nominal battery voltage matches the selected charge
voltage.
The OptiMate Lithium is ready to automatically reset the BMS system within an advanced
battery, indicated by LED #3 flashing 5 times every 15 seconds as reset pulses are
delivered. After connection of the battery to the charger the battery's BMS should reset
within 15-20 seconds, after which the program continues to the next step.
Charger will not proceed without user interaction.
1b
LED #2 REVERSE POLARITY:
2
The charger is electronically protected so no damage will result, and the output will
remain disabled until the connections are corrected.
16V
VOLTAGE SAFETY CHECK:
12.8V (#1a) and 16V LEDs (#1b) alternate and green test LED (#6)
lights.
12.8V is selected and a battery with voltage exceeding 14.8V is connected.
Connected battery may be 16V.
Action: Disconnect battery, select 16V.
6
16V (#1b) and 12.8V (#1a) alternate and red test LED (#8) lights.
7
16V (#1b) selected and a battery with voltage below 14.8V is connected:
The connected battery may be 12.8V or it may be a deep discharged 16V battery.
Action: Physically check battery. If nominal voltage is 12.8V, disconnect battery and select
12.8V.
If nominal voltage is 16V, push and hold finger on SELECT pushbutton. After 5 seconds
program will proceed to STEP 3.
TEST LEDs #6/7/8 indicate the battery condition prior to charging. Consult the table on
page 2 to match TEST LED indication to an estimated state of charge percentage (SOC%).
During the test:
OPTIMIZE minimum charge time is set according to the test result, varying between 10
minutes for a battery with 80% or higher state of charge to 120 minutes
for a battery with 40% or less state of charge.
6
7
Ambient temperature is measured to determine charge voltage parameters.
Charging commences after 10 seconds.
%
V
Confirms AC power supply to the charger and selected battery
for batteries with a battery management system (BMS)
IMPORTANT! Before proceeding,
Lights when the battery connections are incorrect.
0
10
30
7
8
8
0.5V
12.80V
13.00V
60
90
100%
6
6
7
7
13.13V
13.3V
13.6V+

Werbung