6.2

Dip-switch

DIP
Description
DIP1
Control 1-5 function.
DIP2
Direction selection.
DIP3
Restore automatic closing time. 50%
DIP4
Automation status at power on.
Indicates how the control panel
considers automation when po-
wered up.
6.3

Jumper

Jumper Description
JR3
Incorporated radio receiver.
JR4
Overtravel reduction.
Reduces the overtravel distance
for the door wing.
JR6
Application type.
JR10
Maximum power start.
NIO
Electronic antifreeze system.
Maintains motor function even
at low ambient temperatures.
NOTE: for correct operation, the
control panel must be exposed
to the same ambient tempera-
ture as the motors.
SO
Reversal safety switch function. With the automation blocked,
6→4
Control 1-6 function.
OFF
Step-by-Step.
Opens towards right.
Immediate if 6→4=OFF.
NOTE: the setting of DIP3=OFF
and 6→4=OFF is recommended
for the immediate reclosing of
the barriers.
Open.
If DIP1=OFF, the first command
1-5 activates the closing.
If DIP1=ON, the first command 1-5
activates the opening.
NOTE: with a limit switch instal-
led, preferably set DIP4=OFF.
OFF
Disabled.
Disabled.
Sliding gate.
Disabled.
The motor starts with the voltage
set with RF.
Enabled.
ATTENTION: do not use with
E1AJ.
if the contacts 1-8 or 41-8 are
open, it is possible to activate the
opening operation.
NOTE: after the activation of the
proximity limit switch closes the
opening of the safety contact 1-8,
41-8 provokes the STOP during
the closing phase.
Closing.
32
ON
Opening.
Opens towards left.
100%
NOTE: the setting of DIP3=ON is
recommended for overhead and
sectional doors, and condomi-
nial entrances.
Closed.
The first command 1-5 activates
the opening.
NOTE: the automatic closing will
not be the first command, even
if enabled.
If the automatic closing function is
not used, preferably set DIP4=ON.
ON
Enabled.
Enabled.
NOTE: preferably set JR4=ON
if the door wing performs an
excessive overtravel.
Other applications.
Enabled.
The motor starts at maximum
power for 1 s.
Disabled.
With the automation blocked, if
the contacts 1-8 or 41-8 are open,
any operation is impossible.
Stop.