Technical Data
Motor
kW
Pump RPM
rpm
Weight
kg
Max dp
kPa
Max Q
m
3
/h
Sound Level*
)
dB(A)
without silencing enclosure
with silencing enclosure
Inlet/Outlet
mm
*
)
with exhaust silencer, 1 m
Installation
1.
Mount the fan on the mounting bracket.
2. Connect the ducting to both the inlet and the
outlet of the fan before starting. This fan is an
overload type fan and will not function cor-
rectly without being connected to the ductwork
giving suffi cient restriction.
3. The electrical connections may only be made
by a qualifi ed electrician. A separate lockable
disconnect should be installed next to the fan.
Check for correct motor rotation.
2015-06-11
5.5
3000
180
9.5
1100
79
66
108/100
4. Thermal overload protection must be installed
5. Extra silencing can be installed if the outlet
6. If the outlet is vertical, rain protection should
RAF 500S - 11
Pressure loss
kPa
Pu
10
8
6
4
2
0
200
400
600
1
2
3
4
5
kW
P
according to the prevailing electrical code and
adjusted by a qualifi ed electrical technician.
sound level is to be lowered from 100 db(A) to
70 db(A).
be installed.