Herunterladen Inhalt Inhalt Diese Seite drucken

Fig. 14 - Superior LIA Installationsanleitung

Kanalisations-set
Vorschau ausblenden Andere Handbücher für LIA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
- Fix the cable using the clamp (7) supplied, as shown opposite. Place
the latch fastener (6) in the points indicated and thread the cable. (Fig.
14-15)

Fig. 14

Fig. 15
a
Make sure that the cable does not come into contact with
parts that heat up.
- Graft the 2 PIN terminal to the other end of the cable in position AUX
1 on the board, as shown opposite (Fig. 16) and in the stove wiring
diagram.
Fig. 16
- Fix the earth cable onto the board as shown in the stove wiring
diagram.
10
7
DT2033962-00
6
DT2034069-00
H07031720 / DT2002253 – 01
- Graft the 2 PIN (9) terminal in position N.H2O on the board as shown,
in order to stop the stove from operating in the "NIGHT" MODE (Fig.
17).
Fig. 17
- Refit the cast-iron plate, the front grille and the cladding in the reverse
order of disassembly.
- Remove the left side seal (H) by undoing the self-tapping screws that
retain it. (Fig. 18)
Fig. 18
H
- Open the tank cover and turn the sensor support pipe (I) until seeing
the screw heads. Remove the first screw (L) as shown in the figure,
making sure it does not fall into the tank. (Fig. 19)
Fig. 19
- Push the sensor inside the pipe until it touches the other screw.
- Re-mount the side seal.
- Re-mount the casing in the reverse order followed for mounting.
- Fix the M5x35 screw onto the guard (2) and thread it through the
centre of the hole cap (N) as in figure 20.
Fig. 20
DT2034071-00
L
I
DT2034072-00
8
N
2
DT2034133-00