Operate CANview

In addition to the indicated settings the following parameters have to be set in
the used target Software (ecolog 100plus, CANmon, etc.):
• communication via CAN
• CAN baud rate (default setting 125Kbits/s)
• CAN interface (device identifier) corresponding to the VCI Configurator.
When the communication has been started CANview is initialised using the previ-
ously defined parameters and it is ready for the data exchange between RS232
and CAN.

Deinstallation of the VCI software

The deinstallation is made under menu "Start"
"Software"
"ifm VCI-Interface".

Diagnostic LEDs

The LEDs indicate the following functions during communication via the CAN and
RS232 interfaces:
LED
Status
CAN
OFF
ON
Flashing approx. 20 Hz
(synchronously with ERROR)
ERROR
OFF
Flashing approx. 20 Hz
ON
OFF
ON
RS232
OFF
ON
Flashing approx. 20 Hz
(synchronously with ERROR)
CAN
"Settings"
"System control"
Meaning
No data are transmitted
CAN communication active
Error CAN
Normal mode (no error)
Error RS232 or CAN
No supply voltage
Normal mode
RS232 communication inactive
RS232 communication active
Error RS232