Function settings (continued)
No Function
Filter maintenance and fan power up setting
*1
against filter choking
2 Lossnay core maintenance indicator setting
5 Automatic recovery setting after power interruption
6 Indoor negative pressure setting
7 Indoor positive pressure setting
8 Max. fan speed setting during the first 30 minutes
9 Delay start setting for air conditioner starting
13 Exhaust fan setting during air conditioner defrosting
Exhaust fan setting at OA temperature lower
14
than -15 ˚C
15 Interlock mode setting
28 Pulse input setting
Night-purge setting 1)
*30
Air volume
Night-purge setting 2)
*31
Outdoor and indoor temperature gap
Night-purge setting 3)
*32
Threshold of outdoor temperature
Night-purge setting 4)
*33
Time span for memorizing
*34 Input priority setting
36 Outdoor temperature display setting
37 Indoor temperature display setting
38 Calculated supply air temperature display setting
39 Temperature exchange efficiency setting (10 digit) Setting Data 0 to 9 -- > 10 digit of temperature exchange efficiency 0 to 9
40 Temperature exchange efficiency setting (1 digit) Setting Data 0 to 9 -- > 1 digit of temperature exchange efficiency 0 to 9
*41 Outdoor temperature correction
*42 Indoor temperature correction
*51 Automatic ventilation mode setting
Automatic ventilation mode setting 1)
*52
Outdoor and indoor temperature gap
Automatic ventilation mode setting 2)
*53
The lowest outdoor temperature setting
Automatic ventilation mode setting 3)
*54
The lowest indoor temperature setting
*55 Supply fan power up setting
*56 Exhaust fan power up setting
Operation monitor output synchronized with
57
exhaust fan or supply fan
By-pass monitor output or Pre-heater output set-
58
ting
Pre-heater setting 1)
*59
ON temperature
Pre-heater setting 2)
*60
OFF interval
*61 Fan speed for air volume "High" input
*62 Fan speed for air volume "Low" input
*63 External fan speed input setting (0 - 10 VDC)
100 Initialization
This table shows the summary of function settings. Please refer to the following pages for more details.
The functions indicated with * are newly added or modified from Lossnay LGH-RX
The functions indicated with "N/A" in the "DIP-SW No." column are available only when using with remote controller PZ-61DR-E.
Eng-14
0
1
2
Indicator
Indicator N/A
Dip-SW
available
Fan power
priority
Fan power
up N/A
up N/A
N/A
Available
-
Stop when
Start when
Dip-SW
the power
the power
priority
is On
is On
Dip-SW
Supply 1
N/A
priority
down
Dip-SW
Exhaust 1
N/A
priority
down
N/A
Available
-
Dip-SW
N/A
15 min
priority
Dip-SW
Stop
No change
priority
Dip-SW
Fan speed
Stop
priority
1 or 2
Dip-SW
ON/OFF
ON inter-
priority
interlock
lock
Dip-SW
Non-pulse
Pulse
priority
input
input
N/A
Fan speed 1 Fan speed 2 Fan speed 3 Fan speed 4
0 ˚C
1 ˚C
2 ˚C
Setting Data 0 to 15 -- > The lowest outdoor temperature for Night-purge 15 ˚C to 30 ˚C
24 hrs
48 hrs
72 hrs
Main unit
Individual
-
input priority
input priority
N/A
Available
-
N/A
Available
-
N/A
Available
-
Setting Data 0 to 14 -- > Outdoor temperature correction -7 ˚C to 7 ˚C
Setting Data 0 to 14 -- > Room temperature correction -7 ˚C to 7 ˚C
Dip-SW
Pattern A
Pattern B
priority
Setting Data 0 to 7 -- > Temperature gap 0 ˚C to 7 ˚C
Setting Data 0 to 15 -- > Lowest outdoor temperature 10 ˚C to 25 ˚C
Setting Data 0 to 15 -- > Lowest indoor temperature 15 ˚C to 30 ˚C
N/A
1 level up 2 level up 3 level up 4 level up
N/A
1 level up 2 level up 3 level up 4 level up
EA fan
SA fan
Dip-SW
monitor
monitor
priority
output
output
Operation
By-pass
Dip-SW
monitor
monitor
priority
output for
output
Pre-heater
0 ˚C
-1 ˚C
-2 ˚C
1 hr
2 hrs
3 hrs
Dip-SW
Fan speed
Fan speed
priority
4
3
Dip-SW
Fan speed
Fan speed
priority
2
1
Dip-SW
N/A
Pattern X
priority
-
Initialize
-
-E series.
5
Setting Data
3
4
5
Indicator
available
-
-
Fan power
up available
-
-
-
Return to the
state before
-
-
interruption
Supply 2
-
-
down
Exhaust 2
-
-
down
-
-
-
30 min
-
-
-
-
-
No change
-
-
External
OFF inter-
input given
-
lock
priority
-
-
-
-
3 ˚C
4 ˚C
5 ˚C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Free
-
-
setting
-
-
SA fan
monitor
-
-
with delay
operation
-
-
-
-3 ˚C
-4 ˚C
-5 ˚C
4 hrs
5 hrs
-
-
-
-
-
-
-
Pattern Y
Pattern Z
-
-
-
-
Factory
DIP-SW
setting
No.
6
7
-
-
0
5-5
-
-
0
N/A
-
-
0
5-4
-
-
0
2-4
-
-
0
2-5
-
-
0
N/A
-
-
0
5-1
-
-
0
5-3
5-3
-
-
0
5-9
5-7
-
-
0
5-8
-
-
0
2-2
-
-
0
N/A
6 ˚C
7 ˚C
5
N/A
2
N/A
-
-
0
N/A
-
-
0
N/A
-
-
0
N/A
-
-
0
N/A
-
-
0
N/A
7
N/A
0
N/A
7
N/A
7
N/A
-
-
0
2-7
0
N/A
6
N/A
1
N/A
-
-
0
N/A
-
-
0
N/A
2-8
-
-
0
5-2
-
-
0
5-6
-6 ˚C
-7 ˚C
0
N/A
-
-
0
N/A
-
-
0
2-9
-
-
0
2-10
2-3
-
-
0
2-6
-
-
0
N/A