,SETUP – CHANNELS – PWM
MAXIMUM,
Maximum channel intensity adjustment (32768-65535)
Here you can enter the maximum value for the specific channel. The channel output will not get above the
adjusted maximum value.
Press the UP-DOWN button to choose the desired channel.
Press the ENTER button to change the value of the choosen channel. The lower three digits start to blink.
With the UP-Down buttons it is possible to change the value by 1.
Press the ENTER button to choose the upper two digits. With the UP-DOWN buttons you can change the
value by 1.000.
Pressing the ENTER button again, you go back where you can choose the channel.
,SETUP – CHANNELS – RISE OF
CURVE,
With this value possible to set the rise of the dimming curve. The value is the GAMMA parameter of the
calculated curve. If the GAMMA is 1, the curve is linear. The highest GAMMA can be 10.0. As higher the
GAMMA value so slow will be the increasing light power in lower PWM range, but so faster in higher PWM
range.