Address
Type
Function
107
S
3 / 4
108
S
3 / 4
109
U
3 / 4
110
U
3 / 4
111
U
3 / 4
112
U
3 / 4
113
U
3 / 4
114
U
3 / 4
115
U
3 / 4
116
U
3 / 4
117
U
3 / 4
118
U
3 / 4
119
U
3 / 4
120
U
3 / 4
121
U
3 / 4
122
U
3 / 4
123
U
3 / 4
124
U
3 / 4
125
U
3 / 4
126
U
3 / 4
127
U
3 / 4
128
U
3 / 4
129
U
3 / 4
130
U
3 / 4
131
U
3 / 4
132
U
3 / 4
133
U
3 / 4
134
U
3 / 4
135
U
3 / 4
136
U
3 / 4
137
U
3 / 4
138
U
3 / 4
139
U
3 / 4
140
U
3 / 4
141
U
3 / 4
142
U
3 / 4
143
U
3 / 4
144
U
3 / 4
145
U
3 / 4
146
U
3 / 4
147
U
3 / 4
148
U
3 / 4
149
U
3 / 4
150
U
3 / 4
151
U
3 / 4
152
U
3 / 4
153
U
3 / 4
154
U
3 / 4
Copyright of the European Union is effective (Copyright EU) (c) 2019 GENEREX Systems GmbH, Hamburg, Germany, All rights reserved
TEL +49(40)22692910 - EMAIL generex@generex.de - WEB www.generex.de (This and all other product datasheets are available for download.)
Name
TEMPDEG
AUTONOMTIME
STATUS (e. g. UPS normal =
"4", Powerfail = "12", Battery test
running = "68", Bypass = "5")
BATTVOLT
INFREQ0
INFREQ1
INFREQ2
CNT_PF
(SNMPALARMS&0x1)
(SNMPALARMS&0x2)>>1
(SNMPALARMS&0x4)>>2
(SNMPALARMS&0x8)>>3
(SNMPALARMS&0x10)>>4
(SNMPALARMS&0x20)>>5
(SNMPALARMS&0x40)>>6
(SNMPALARMS&0x80)>>7
(SNMPALARMS&0x100)>>8
(SNMPALARMS&0x200)>>9
(SNMPALARMS&0x400)>>10
(SNMPALARMS&0x800)>>11
(SNMPALARMS&0x1000)>>12
(SNMPALARMS&0x2000)>>13
(SNMPALARMS&0x4000)>>14
(SNMPALARMS&0x8000)>>15
(SNMPALARMS&0x10000)>>1
(SNMPALARMS&0x20000)>>1
(SNMPALARMS&0x40000)>>1
(SNMPALARMS&0x80000)>>1
(SNMPALARMS&0x100000)>>
(SNMPALARMS&0x200000)>>
(SNMPALARMS&0x400000)>>
(SNMPALARMS&0x800000)>>
AUX1STATE
AUX2STATE
AUX3STATE
AUX4STATE
TEMP1
TEMP2
TEMP3
TEMP4
TEMP5
TEMP6
TEMP7
TEMP8
AEESerModulePresent(1)
AEESerModulePresent(2)
AEESerModulePresent(3)
AEESerModulePresent(4)
105
v.: 2.0.8 - 2019-02-19 / FW1.76
Description
Temperature C°
Autonomy Time minutes
UPS Status (ASCII HEX), please note
UPSMAN status bytes table below
Battery Voltage V
Input Frequency Hz Phase 1
Input Frequency Hz Phase 2
Input Frequency Hz Phase 3
Powerfail Counter
Alarm Battery Bad
Alarm: On Battery
Alarm: Battery Low
Alarm: Battery Depleted
Alarm: Over temperature
Alarm: Input Bad
Alarm: Output Bad
Alarm: Output Overload
Alarm: On Bypass
Alarm: Bypass Bad
Alarm: Output Off as requested.
Alarm: UPS Off as requested.
Alarm: Charger Failed
Alarm: UPS Output Off
Alarm: UPS System Off
Alarm: Fan Failure
Alarm: fuse failure
Alarm: general fault
Alarm: diagnose test failed
Alarm: communication lost
Alarm: awaiting power
Alarm: shutdown pending
Alarm: shutdown imminent
Alarm: test in progress
AUX Port 1
AUX Port 2
AUX Port 3
AUX Port 4
Sensormanager/SMTCOM sensor 1
Sensormanager/SMTHCOM sensor 2
Sensormanager sensor 3
Sensormanager sensor 4
Sensormanager sensor 5
Sensormanager sensor 6
Sensormanager sensor 7
Sensormanager sensor 8
Status data, for details contact Effekta
Status data, for details contact Effekta
Status data, for details contact Effekta
Status data, for details contact Effekta
Length
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1