General Power Tool Safety
Warnings
WARNING Read all safety warnings and all
instructions. Failure to follow the warnings and
instructions may result in electric shock, fire and/or
serious injury.
Save all warnings and instructions for
future reference.
MIXER SAFETY WARNINGS
1.
Use auxiliary handle(s), if supplied with the
tool. Loss of control can cause personal injury.
2.
Hold
power
surfaces, when performing an operation
where the cutting accessory
hidden wiring or its own cord. Cutting
accessory contacting a "live" wire may make
exposed metal parts of the power tool "live" and
could give the operator an electric shock.
3.
Always be sure you have a firm footing.
Be sure no one is below when using the tool in
high locations.
4.
Hold the tool firmly.
5.
Keep hands away from rotating parts.
6.
Do not leave the tool running. Operate the tool
only when hand-held.
7.
Some material contains chemicals which may
be toxic. Take caution to prevent dust
inhalation and skin contact. Follow material
supplier safety data.
SAVE THESE INSTRUCTIONS.
WARNING:
DO NOT let comfort or familiarity with product
(gained from repeated use) replace strict adherence
to safety rules for the subject product. MISUSE or
failure to follow the safety rules stated in this
instruction manual may cause serious personal
injury.
30.1.2009
Director
tool
by
insulated
may contact

FUNCTIONAL DESCRIPTION

CAUTION:
Always be sure that the tool is switched off and
unplugged before adjusting or checking function on
the tool.
Switch action
Fig.1
CAUTION:
Before plugging in the tool, always check to see
GEA010-1
that the switch trigger actuates properly and returns
to the "OFF" position when released.
To start the tool, simply pull the switch trigger. Release
the switch trigger to stop.
For continuous operation, pull the switch trigger and then
push in the lock button.
To stop the tool from the locked position, pull the switch
trigger fully, then release it.
Indicator lamp
Fig.2
GEB087-1
The green power-ON indicator lamp lights up when the
tool is plugged to the mains. If the indicator lamp is lit but
the tool does not start even if the tool is switched ON, the
carbon brushes may be worn out, or the motor or the
switch may be defective. If the indicator lamp does not
gripping
light up, the mains cord or the indicator lamp may be
defective. When the mains cord is defective, the tool
neither starts nor lights the indicator lamp. When the
indicator lamp is defective, the tool starts without the
indicator lamp lighting up.
ASSEMBLY
CAUTION:
Always be sure that the tool is switched off and
unplugged before carrying out any work on the tool.
Installing shaft
Fig.3
Tighten the shaft with hex nut into the shaft holder as far
as the hex nut comes into contact with the holder.
Hold the notch in the shaft holder with wrench 19 so that
it cannot revolve. With the notch held so, tighten the hex
nut with another wrench 19 in the direction of arrow.
Fig.4
Installing mixing blades
Fig.5
Fig.6
Insert the mixing blade into the shaft and secure it with
the hex bolt.
At this time, position it so that the top end of the hex bolt
always fits to the flat surface on the shaft and tighten the
hex bolt with the provided wrench.
4