Herunterladen Inhalt Inhalt Diese Seite drucken

Disposal; 7 Further Details; Programming Keys; 7.2.1 Level 1 Functions (On-Off Functions) - TEN TNKCE Anweisungen Und Hinweise Für Den Installateur

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 86

6.2) Disposal

As in installation, also at the end of product lifetime, the disassembly
and scrapping operations must be performed by qualified personnel.
This product is made up of different types of material, some of which
can be recycled while others must be disposed of. Seek information
on the recycling and disposal systems envisaged by the local regu-
lations in your area for this product category.
!
Some parts of the product may contain pollutant or
hazardous substances which, if disposed of into the envi-
ronment, may cause serious damage to the environment
or physical health.
As indicated by the symbol in figure 31, disposal of this product in domes-
tic waste is strictly prohibited. Separate the waste into categories for dis-
posal, according to the methods envisaged by current legislation in your
area, or return the product to the retailer when purchasing a new version.
7) Further details
This chapter deals with the options for programming, personalisation, diagnostics and troubleshooting for the TEN gearmotor

7.1) Programming keys

The TEN control unit is fitted with 3 keys which can be used both for the control of the
unit during testing and the programming procedure (Figure 32)
RADIO Within the first 10 seconds after power-up, perform the "RADIO"
function to enable memorisation and deletion of the radio transmitters
OPEN
used with TEN.
RADIO
After this time interval, perform the "OPEN" function to enable the user to
open the door or scroll up through the programming steps.
STOP
The STOP key stops the manoeuvre; If pressed for more than 5 seconds,
SET
it enables entry to programming mode.
CLOSE
The "CLOSE" key enables the user to close the door or scroll down
through the programming steps
!
During the manoeuvre, whether opening or closing, all keys execute the STOP function to shut down motor move-
ment.
7.2) Settings
The TEN control unit is equipped with a number of programmable
functions; function settings are entered by means of the 3 keys on
the control unit: [▲] [▼] and [Set] and are displayed by means of
3 leds: L1, L2, L3.
The programmable functions available on TEN are divided into 2 levels:
Level 1: functions settable in ON-OFF mode (enabled or disabled);
7.2.1) Level 1 functions (ON-OFF functions)
Table 14: List of programmable functions: Level 1
NO. Description
L1
Closing speed
L2
Opening speed
L3
Automatic closure
During normal operation of TEN, leds L1, L2 and L3 are lit or off depending on the status of the associated function, for example L3 is lit if
the function "Automatic closure" is enabled. L1 also displays the status of the "radio" function in the first 10 seconds after power-up.
N.B.: if the motor speed is set to "high" on opening and closing and the motor force is set to "high", the deceleration
phases are disabled (excluding deceleration in closure on approach to the mechanical stop).
16
example
This function enables the selection of the motor speed during the closing manoeuvre, from 2 levels:
"high" and "low". If the function is not enabled, the speed is set to "low".
This function enables the selection of the motor speed during the opening manoeuvre, from 2 levels: "high"
and "low". If the function is not enabled, the speed is set to "low".
Automatic closureThis function enables automatic closure of the door after a programmed pause; the
default Pause Time is set at 30 seconds but may be modified to 15 or 60 seconds (see table 16).
If the function is not enabled, operation is set to "semi-automatic"
Local legislation may envisage serious fines in the event of abusive
disposal of this product.
1. Disconnect the electrical mains from the automation.
2. Disassemble all devices and accessories, following the procedure
described in chapter "3 Installation" in reverse order
3. Where possible, separate all parts that can be recycled or dis-
posed of as classified waste, such as metal and plastic parts,
electronic boards, batteries etc.
4. Sort all groups and deliver separated waste to an authorised dis-
posal firm in compliance with local regulations.
31
32
in this case leds L1, L2, and L3 indicate a function, if lit the function
is enabled, if off the function is disabled; see Table 14.
Level 2: parameters settable on a scale of values (from 1 to 3); in
this case each led L1, L2, L3 indicates a set value from the possible
3; see Table 16.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tn2030Tn2020

Inhaltsverzeichnis