Installation

Step 1: Select installation location for the hybrid module

Select an installation location within the wireless range of the alarm panel (max. 500 m outdoors).
Make sure the external power supply unit has a suitable 230 V power supply.
Before starting installation, identify a suitable installation location for the hybrid mod-
ule using the wireless test box if necessary.
Note
Incorrect or unclean installation work may lead to erroneous interpretation of signals,
the consequences of which may include false alarms. The costs incurred by potential
dispatches of rescue services, such as the fire service or police, must be borne by the
operator of the system.
To ensure trouble-free operation, the hybrid module must NOT be installed:
• at a distance of less than 1 m from large metal structures such as metal doors
or frames, water tanks, refrigerators or vehicles
• at a distance of less than 1 m from household electrical systems, distributors
or metal pipes
• inside metal housings
• close to the main power supply, or close to water or gas pipelines
• close to high-voltage devices or electronic devices such as computers, photo-
copiers or other wireless devices

Step 2: Open the hybrid module cover

• Remove the two screws and open the cover (Image 2)
Image 2