Operation
Installation
Installing the Safety Guard Zone
radio module
The radio module creates a stationary warning
zone and triggers further actions on industrial
trucks present in this warning zone.
NOTE
Install the radio module as high up as possible
in order to guarantee optimum radio coverage.
Installation via magnet
The Safety Guard Zone radio module can be
mounted to metallic surfaces using a magnet.
 Mount a self-adhesive magnet with the
sticky side on the rear of the housing.
 Attach the radio module in the intended
location.
 Connect the radio module to a 12-24-V DC
power supply via the connector plug.
The radio module starts and the operating
status LED flashes green.
Installation via screw joint
 Remove the holes cover (1).
 Insert a release tool in the opening (2) and
release the upper part of the housing at four
points.
 Remove the upper part of the housing.
 Mark the four fixing points (3) on the ground.
 Drill mounting holes and then insert dowels
if these are required.
 Secure the radio module with four screws
and attach the upper part of the housing.
Make sure that the upper part of the housing
engages fully.
 Connect the radio module to a 12-24-V DC
power supply.
The radio module starts and the operating
status LED flashes green.