Safety
General regulations
Application
Norms and regulations
General regulations
This documentation contains important
information, which is a base for safe
and reliable installation, commissioning
and operation of the Econoflame R6000
boiler. All activities described in this
document may only be excecuted by
authorized companies.
Changes to this document may be ef-
fected without prior notice. We accept
no obligation to adapt previously deliv-
ered products to incorporate such
changes.
Only original spare parts may be used
when replacing components on the
boiler, otherwise warranty will be void.
Application
The Econoflame R6000 boiler may be
used for heating and hot water pro-
duction purposes only. The boiler
should be connected to closed systems
with a maximum temperature of 100ºC
(high limit temperature), maximum
setpoint temperature is 90ºC.
Norms and regulations
When installing and operating the
boiler, all applicable norms (european
and local) should be fulfilled:
•
Local building regulations for install-
ing combustion air and flue gas sys-
tems;
•
Regulation for connecting the boiler to
the electrical appliance;
•
Regulations for connecting the boiler
to the local gas network;
•
Norms and regulations according to
safety equipment for heating systems;
•
Any additional local laws/regulations
with regard to installing and operating
heating systems.
The Econoflame R6000 boiler is
CE approved and applies to the
following European standards:
−
92 / 42 / EEC
Boiler efficiency directive
−
90 / 396 / EEC
Gas appliance directive
−
73 / 23 / EEC
Low voltage directive
−
89 / 336 / EEC
EMC directive
−
EN 656
Gas-fired central heating boilers –
Type B boilers of nominal heat input
exceeding 70 kW but not exceeding
300 kW
−
EN 15420
Gas-fired central heating boilers -
Type C boilers of nominal heat input
exceeding 70 kW, but not exceeding
1000 kW
−
EN 15417
Gas-fired central heating boilers -
Specific requirements for condensing
boilers with a nominal heat input
greater than 70 kW but not exceeding
1000 kW
−
EN 13836
Gas fired central heating boilers -
Type B boilers of nominal heat input
exceeding 300 kW, but not exceeding
1000 kW
−
EN 15502-1
Gas-fired central heating boilers -
Part 1: General requirements and
tests
−
EN 55014-1
Electromagnetic compatibility - Re-
quirements for household appliances,
electric tools and similar apparatus -
Part 1: Emission
−
EN 55014-2
Electromagnetic compatibility - Re-
quirements for household appliances,
electric tools and similar apparatus -
Part 2: Immunity - Product family
standard
−
EN 61000-3-2
Electromagnetic compatibility (EMC) -
Part 3-2: Limits - Limits for harmonic
current emissions (equipment input
current 16 A per phase)
−
EN 61000-3-3
Electromagnetic compatibility (EMC) -
Part 3-3: Limitation of voltage
changes, voltage fluctuations and
flicker in public low-voltage supply
systems, for equipment with rated
current 16 A per phase and not sub-
ject to conditional connection
−
EN 60335-1
Household and similar electrical appli-
ances - Safety - Part 1: General re-
quirements
−
EN 50165
Household and similar electrical appli-
ances - Safety - Part 2-102: Particular
requirements for gas, oil and solid-
fuel burning appliances having
electrical connections
Additional national standards
Germany:
−
RAL - UZ 61 / DIN 4702-8
Switzerland:
−
SVGW
Austria:
−
ÖVGW
Netherlands:
−
NOx staatsblad 344 (1994)
−
GASKEUR BASIS
−
GASKEUR SV
−
GASKEUR HR107
Belgium:
−
HR TOP
3