Herunterladen Inhalt Inhalt Diese Seite drucken

Reprogramming Procedure - Motostar LIVI series Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 82

Reprogramming procedure

Accessing programming. Press the PROG button A for at least 3 seconds and re-
>3''
lease it (within 6 seconds) as soon as the PROG LED flashes and the backlighting on
<6''
the buttons comes on as shown in figure B.
PROG
A
SW3
PROG
beep
4
3
2
SW3
Programming the call keys. Press the door lock release
and AUX2 3 buttons.
<1''
On the entry panel, press the call key to associate with the internal extension 4: an
PROG
acoustic signal will confirm that the setting was stored. Hang up the receiver again.
Repeat the same operations for the other extensions.
SW3
5
>3''
<6''
PROG
PROG
8
6
G
M1
SW3
SW3
BOUT
Exiting programming. Briefly press the PROG button E: the PROG LED goes off. N.B.
M2
If no action is performed, the procedure will automatically end after 30 minutes.
Programming button type. At the "Programming Call Buttons" stage, press the PROG
button F for at least 3 seconds and release it (within 6 seconds) as soon as the PROG
I
LED comes on and the backlighting on the buttons flashes as shown in figure G ,
M1
BOUT
entring the "Programming button type" procedure.
Press the first button on the entry panel in the position marked H until the backlit LEDS
M2
stop flashing I and remain lit.
At the end, to exit programming, briefly press the PROG button E : the PROG LED goes
off. If no action is performed, the procedure will automatically end after 30 minutes.