Supply Point; Circuitry Of The Relay Outputs - OBID ID AWE6000.A-A Montage / Installation

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
OBID

11.1. Supply point

Please connect the 230V current supply to the terminals located on the mounting plate. A suitable
cable type would be a standard 3x1,5mm
Please connect the protective conductor to the appropriate terminal X5.3 (PE).

11.2. Circuitry of the relay outputs

The evaluation unit has 2 relay outputs, which can be used as make contact or break contact. De-
tection of an authorized transponder is emitted as a pulse at relay 1 – pulse duration may be freely
adjusted – and generally serves as a trigger signal for barriers, door openers etc. Relay 2 makes
contact as soon as a non-authorized ID-code has been identified. All relay connections are on ter-
minal strip X4.
Terminal
X 4.1
X 4.2
X 4.3
X 4.4
X 4.5
X 4.6
Chart 4: Terminal strip X4
FEIG ELECTRONIC GmbH
Installation
2
cable
Configuration of terminal strip X4 – relay outputs
Name
ON
OFF
COM
ON
OFF
COM
Page 46 of 55
.
Explanation
Make contact of relay 1
Break contact of relay 1
Common connection relay 1
Make contact of relay 2
Break contact of relay 2
Common connection relay 2
ID AWE 3000/6000.A-A