1.
Use as directed:
This product serves exclusively lighting purposes and may:
only be used with a voltage of 230V/50Hz.
only be used in dry condition,
not in damp or dirt-endangered rooms.
not in areas of high air humidity.
not be exposed to strong mechanical loads or to strong contamination.
only be installed and operated after a condition inspection if the product is dirty or
has been moistened through storage.
If these points named above are not adhered to, a short circuit or electrical shock may
occur!
2.
Technical Data:
Operating voltage:
230V/ 50Hz
Safety class:
I
Bulb:
QR-LP111, G53, 2x50W max./ TC-DE, G24q-3, 2x26 W
Dimensions (L x W x H):
36,2cm x 36,2cm x 19,0cm
Weight:
3,5 kg
Importer:
SLV Elektronik GmbH
3.
Assembly
Attention: Use only parts, which belong to the product! Otherwise the product or the
installation might not be sufficiently safe. Switch off the power of the mains supply line or
respectively of the connection lead before doing any works.
a)
Assembly place:
Make sure that the product is mounted on a stable, even and tilt-fixed background and
is prevented from falling down when installed. The product should be placed at least so
far from the illuminated surface, as indicated as minimum distance on the type plate of
the spot:
.Pay special caution to easily inflammable objects (e.g. curtains) or
electric connections.
b)
Separate Assembly Steps
The fitting is suitable for installation in cavity ceilings. Opening size: 33/33 cm.
Note the minimum distances in the ceiling – 10 cm horizontally and 18 cm
vertically.
Prepare the opening.
Inserting the bulbs
QR-LP111: Screw on the contact flaps. Push the bulb into the bulb holder. Ensure
a secure fit.
TC-DE: Remove the protection glass. Touch energy-saving-lamps on the plastic
housing, not on the bulb glass. Stick the bulb into the socket. Put the protection
glass back on.
Electrical Connection
The electric connection may be executed only by an electric expert who is familiar
with the valid directives.
The product must be able to be separated by an all pole separation from the
current supply.
3
Do not damage the power supply line in the ceiling/wall, i.e. by drilling, screws or
strong bending. This can lead to a short circuit.
For electric connection of the ballst attach the black or brown wire (live conductor)
of the main power supply with the clamp L and the blue wire (neutral conductor) of
the main power supply with the clamp N. The green-yellow wire (protective
conductor) of the main power supply has to be tightly screwed into the earth
clamp
of the product.
Preparing the 12 V power supply
The transformer should be used up to 80 % of its capacity. The total watt power of
the connected light fittings must not exceed the power output of the transformer.
The distance between spot and transformer should be at least 20 cm. The
conductor length between a electronical transformer and a lamp may not be
longer than 2 metres. (Electromagnetic Emission). Note the manufacturers
information for the transformer.
Secure the strain relief.
Direct the recessed downlight into the opening, with the retaining springs pointing
upwards.
Ensure a safe hold of the fitting.
The product is now ready for operation.
4.
Operation:
Information for the user:
Operate the product only if it is working correctly. Switch off the product with a malfunction
immediately and operate it again only after examination by an electrical specialist.
This is the case, when:
visible damages appear.
the product does not work.
smoke, steam or crackling sounds appear.
an overheating is recognisable.
Repairs of the product or work on mains voltage-prominent sections may only be carried out
by qualified electricians.
Attention: Here exists mortal danger from an electric shock!
How to avoid failure and fire risk:
Do not fasten or hang anything on the product!
Provide free air circulation - cover nothing!
Do not hang anything on the product, especially no decoration and no electrically
conducting objects.
Never let children play unsupervised with electric products! Children can not always
estimate dangers in dealing with electric energy correctly.
What is to do if a bulb is defect or does not work?
Disconnect the product from power, before you exchange the bulbs.
Caution: Let the bulb cool down first before replacement – otherwise
considerable risk of injury exists because of the hot surface.
Replace the bulbs only with bulbs of the same data like socket, power and
capacity. Every other sort of bulb can lead to damages of the light.
5.
What else has to be considered?
Disconnect the product from power, before you...
clean or maintain the product.
do any works on the product or its components (electric expert).