c)
Maximum Power Rating
The decade has a total maximum power rating of 1 Watt.
 The maximum power rating shall not be exceeded, as damage or even destruction of
the decade may occur.
 Limit applied voltage in relation to maximum activated resistor according to table 1.
 DO NOT APPLY ANY voltage to the decade without activated resistor!
 This may lead to immediate destruction of the decade and in combination with high
voltages even to personal injury!
The maximum operational voltage V
maximum power rating of 1W is calculated in the following way with the maximum
R
activated resistor R
Table 1 shows maximum operational voltage V
resistor R
at maximum power rating of 1W:
Maximum activated resistor
on
on
kΩ
kΩ
:
Maximum operational voltage
max
on
[17]
, which is allowed to be applied according to
V
in relation to maximum activated
1,7 V
2,4 V
3 V
3,4 V
max
5,4 V
7,7 V
9,4 V
max
10,9 V
17,3 V
24,4 V
30 V
34,6 V
54,7 V
77,4 V
I
Maximum resulting current
1,7 A
1,2 A
1 A
866 mA
547 mA
387 mA
316 mA
273 mA
173 mA
122 mA
100 mA
< 100 mA
< 100 mA
< 100 mA