7. Setup
Installation
Mount the evaluation unit onto a wired AS-i FC or FC-E coupling module and
then onto a 35 mm rail or fasten it onto a mounting device.

Electrical connection

The supply of the fail-safe switches comes from the AS-i system. Do not
connect the inputs with an external potential.
Connect the M12 socket I-1 of the evaluation unit to the corresponding connec-
tions of the fail-safe switch or the chain of fail-safe switches (L+, TE, L- and OUT).
I-1
connection fail-safe switches
1: L+
2: TE (clock input)
3: L-
4: OUT (output signal)
5:
When the switching output O-3 is used, an FC-E coupling module must be used!
Cover the possibly unused socket O-3 with the enclosed protective cap to main-
tain the specified protection rating.

Parameter setting

Depending on the number of connected fail-safe switch versions the
parameters must be set.
Fail-safe switch
GI5002
GM503S
GM504S
GM505S
GI505S
GG505S
O-3
switching output PNP
1:
2:
3: GND
4: O-3
5:
Even number
D01=1
D01=1
D01=1
D01=1
D01=1
D01=1
EVALUATION UNIT
ERROR
I-1
O-3
Odd number
D01=0
D01=0
D01=1
D01=1
D01=1
D01=1
G1506S
AUX