Herunterladen Diese Seite drucken

Axor Starck Organic Gebrauchsanleitung Seite 3

Vorschau ausblenden Andere Handbücher für Starck Organic:

Werbung

S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
F A U L T
⁄ Mixer stiff
⁄ Mixer dripping
⁄ Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
A S S E M B L Y (see page 04)
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C ⁄ 4 min
C A U S E
⁄ Cartridge defective, calcified
⁄ Cartridge defective
⁄ Hot water limiter incorrectly set
⁄ Crossflow
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 06)
To adjust the hot water limiter. Using a hot water
limiter in combination with a continuous flow
water heater is not recommended.
D I M E N S I O N S (see page 07)
F L O W D I A G R A M
(see page 07)
free flow
S P A R E P A R T S (see page 10)
+
S P E C I A L A C C E S S O R I E S (see page
10)
O P E R A T I O N (see page 08)
C L E A N I N G (see page 09)
R E M E D Y
⁄ Exchange cartridge
⁄ Exchange cartridge
⁄ Set hot water limiter
⁄ Exchange cartridge
0 3
EN

Werbung