General

ELK 15 is an electric heater that can be used to supple-
ment the heating capacity of your NIBE climate unit.
When the heating demand is greater than the climate
unit's capacity, the electric heater connects automatic-
ally. The electrical equipment is adapted to the climate
unit's function.
The electric heater is in principle an immersion heater
mounted in a water container or an electric boiler
without a water heater. The stainless steel electric coils
and electric boiler tube are made of stainless steel (SIS
2333) which gives a very good service life.
Thanks to a small water volume and a well-insulated
electrical heater, ELK 15 has very small heat losses.

Compatible products

Connection is different depending on which product
ELK 15 is to be used with.
These products can be connected directly to ELK 15:
F1345
SMO 20
SMO 40
These products require the accessory AXC 40:
F1145
F1155
F1255
VVM 320
VVM 325
VVM 310 requires the accessory DEH 310 .
VVM 500 requires the accessory DEH 500.
Contents
1 x
Immersion heater

Assembly

The electric heater must be installed upright (see image
below).
Free space of 500 mm is required in front of the water
heater for service. If this is not possible, detachable
connections must be used.